Sign inSubmit
Tips: “quotes” for a phrase · author:Lee · a DOI goes straight to its article

13 results for “oscillating heat-pipe”

Set a search alert
Research ArticleOpen accessPhrase in the titleApplied a Closed-Loop Oscillating Heat-Pipe Heat Exchanger to Increasing Oil Yield in Pyrolysis ProcessN. Panyoyai, T. Wongsiriamnuay, S. SangsrichanProblem statement: A Closed-Loop Oscillating Heat-Pipe (CLOHP) heat exchanger was a heat exchanger with one of the most promising conductivity capacities because of its higher cooling and condensing potential. Therefore, the aims of this study were to design and fabricate a CLOHP to be applied to increasing oil yield in the pyrolysis process. Approach: Two types of oscillating heat-pipe arrangements-parallel … …Energy Research Journal, Vol. 1, Issue 1 · 30 Jun 2010 · 7,620 accessesView PDFCite
Research ArticleOpen accessPhrase in the titleEffect of Inner Diameter and Inclination Angles on Operation Limit of Closed-Loop Oscillating Heat-Pipes with Check ValvesP. Meena, S. Rittidech, P. TammasaengThis research was to study the effect of inner diameter and inclination angles on operation limit of a closed loop oscillating heat pipes with check valves (CLOHP/CV). A set of CLOHP/CV was made of copper tubes in combination of following dimension: 1.77 and 2.03 mm inside diameter: 10 turn, with R123 was used as the working fluid. The working fluid … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 2 · 30 Jun 2008 · 7,145 accessesView PDFCite
Research ArticleOpen accessPhrase in the titleEffect of Evaporator Lengths and Ratio of Check Valves to Number of Turns on Internal Flow Patterns of a Closed-Loop Oscillating Heat-Pipe With Check ValvesS. Rittidech, P. Meena, P. TerdtoonA visualization study of the internal flow patterns of a closed-loop oscillating heat-pipe with check valves (CLOHP/CV) at normal operating condition for several evaporator lengths (Le), and ratio of check valves to number of turns (Rcv) has been conducted. This article describes the effects of varying Le, and Rcv on flow patterns. The CLOHP/CV used a Pyrex glass tube with … …American Journal of Applied Sciences, Vol. 5, Issue 3 · 31 Mar 2008 · 7,266 accessesView PDFCite
Research ArticleOpen accessPhrase in the titleEffect of Geometry and Dimensionless Parameters on Heat Transfer Characteristics of a Closed–end Oscillating Heat-pipe at Vertical PositionS. Rittidech, K. PhalasinThis heat transfer characteristics of a closed-end oscillating heat-pipe (CEOHP) depend on a number of parameters. They are the number of turns, inner diameter of the tube, aspect ratio and the dimensionless parameters of heat transfer. The CEOHPs used to employ a copper tube with inner diameter of 0.66, 1.09 and 2.03 mm. The lengths of the evaporator, adiabatic and … …American Journal of Applied Sciences, Vol. 2, Issue 11 · 30 Nov 2005 · 6,642 accessesView PDFCite
Research ArticleOpen accessPhrase in the titleCPU Cooling of Desktop PC by Closed-end Oscillating Heat-pipe (CEOHP)S. Rittidech, A. Boonyaem, P. TipnetThe CEOHP cooling module consisted of two main parts, i.e., the aluminum housing and the CEOHP. The house casing was designed to be suitable for CEOHP. The housing to drilling for insert the CEOHP. The CEOHP design employed copper tubes: Two sets of capillary tubes with an inner diameter of 0.002 m, an evaporator length of 0.05 and a condenser … …American Journal of Applied Sciences, Vol. 2, Issue 12 · 31 Dec 2005 · 8,454 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleEffect of Length Ratios on Heat Transfer Characteristics of Closed-Loop Oscillating Heat Pipe with Non-Uniform DiameterP. Sakulchangsatjatai, P. Pathike, P. TerdtoonProblem statement: Closed-loop oscillating heat pipe is a high performance heat exchanger especially as this heat exchanger has one direction flow of working fluid inside tube. Approach: This research studies the effect of length ratios on heat transfer characteristic of Closed Loop Oscillating Heat Pipe with Non-Uniform Diameter (CLOHP/NUD). The 2.03 and 1.06 mm inner diameter of capillary tube were … …Energy Research Journal, Vol. 1, Issue 2 · 31 Oct 2010 · 7,680 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleEffects of Aspect Ratios and Number of Meandering Turns on Performance Limit of an Inclined Closed-Loop Oscillating Heat PipeN. Panyoyai, P. Terdtoon, P. SakulchangsatjataiProblem statement: The purpose of this research was to determine the effects of aspect ratios and number of meandering turns on performance limit of an inclined closed-loop oscillating heat pipe. Approach: The Closed-Loop Oscillating Heat Pipe (CLOHP) was made of a long copper capillary tube. The geometrical sizes, which were the variable parameters of this study, were as follows; the … …Energy Research Journal, Vol. 1, Issue 2 · 31 Oct 2010 · 8,081 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleEffect of Evaporator Section Lengths and Working Fluids on Operational Limit of Closed Loop Oscillating Heat Pipes with Check Valves (CLOHP/CV)P. Meena, S. Rittidech, P. TammasaengThis research aims to the effect of evaporator section lengths and working fluids on operational limit of closed loop oscillating heat pipes with check valves (CLOHP/CV) with R123 Ethanol and Water were used as the working fluids. A set of CLOHP/CV was made of copper tubes in combination of following dimension: 1.77 mm inside diameter: 10 turns: 5, 10 and … …American Journal of Applied Sciences, Vol. 6, Issue 1 · 31 Jan 2009 · 7,776 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleEffect of Inclination Angle on Performance Limit of a Closed-End Oscillating Heat PipeT. Hudakorn, P. Terdtoon, P. SakulchangsatjataiThis study presents the effect of inclination angle on the performance limit of a Closed-End Oscillating Heat Pipe (CEOHP). The study was divided into 2 corresponding parts. The first part was visual study. The CEOHP was made of Pyrex glass tube with the inner diameter of 1.0 mm, evaporator length of 50 mm and had 10 meandering turns. The lengths … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 3 · 30 Sep 2008 · 7,516 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleWaste Heat Recovery by Closed-Loop Oscillating Heat Pipe with Check Valve from Pottery Kilns for Energy ThriftP. Meena, S. RittidechThis study aims to design, construct and test the waste heat recovery by closed-loop oscillating heat pipe with check valve from pottery kilns for energy thrift, were used the working fluids with a filling ratio of 50%. The (CLOHO/CV) was made of copper capillary tube with inside diameter of 2.03 mm. The lengths of evaporator and condenser section were 20 … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 2 · 30 Jun 2008 · 7,490 accessesView PDFCite