Sign inSubmit
ArticleArticle metrics
Research Article · Free to read · Published 31 March 2008

Effect of Evaporator Lengths and Ratio of Check Valves to Number of Turns on Internal Flow Patterns of a Closed-Loop Oscillating Heat-Pipe With Check Valves

S. Rittidech, P. Meena & P. Terdtoon

American Journal of Applied Sciences, Volume 5, Issue 3, pp. 184–188 · doi.org/10.3844/ajassp.2008.184.188

7,266 accesses5,188 downloads4 citations (Crossref)Journal metrics
Cite Check for updates

Abstract

A visualization study of the internal flow patterns of a closed-loop oscillating heat-pipe with check valves (CLOHP/CV) at normal operating condition for several evaporator lengths (Le), and ratio of check valves to number of turns (Rcv) has been conducted. This article describes the effects of varying Le, and Rcv on flow patterns. The CLOHP/CV used a Pyrex glass tube with inside diameter of 2.4 mm. The evaporator length of 50 and 150 mm. (the lengths of evaporator, adiabatic and condenser were equal) were employed with 10 turns, with Rcv of 0.2 and 1. R123 was used as the working fluid with filling ratio of 50% of internal volume of tube. It was found that the internal flow patterns could be classified according to the Le and Rcv as follows: At the high heat source when the Le decreases the main flow changes from the bubble flow with slug flow to disperse bubble flow. The Rcv decreases the main flow changes from the disperse bubble flow with bubble flow to disperse bubble When the velocity of slug increases, the length of vapor bubbles rapidly decreases and the heat flux rapidly increases.

Licence and reuse

Free to read. This article carries the publisher’s copyright, as printed on it: © 2008 Science Publications. It is free to read; ask us before reusing it.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Rittidech, S., Meena, P. & Terdtoon, P. (2008). Effect of Evaporator Lengths and Ratio of Check Valves to Number of Turns on Internal Flow Patterns of a Closed-Loop Oscillating Heat-Pipe With Check Valves. American Journal of Applied Sciences, 5(3), 184–188. https://doi.org/10.3844/ajassp.2008.184.188

Licence
© Science Publications
Issue
Volume 5, Issue 3
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
Effect of Evaporator Lengths and Ratio of Check Valves to Number of Turns on Internal Flow Patterns of a Closed-Loop Oscillating Heat-Pipe With Check ValvesAmerican Journal of Applied Sciences · Volume 5, Issue 3 · pp. 184–188 · © Science PublicationsDownload