Sign inSubmit
Tips: “quotes” for a phrase · author:Lee · a DOI goes straight to its article
Author

P. Terdtoon

6 articles in our journals

Articles where this person is an author, newest first. People are matched by their name as printed (no ORCID iD is recorded for them), not by name alone; search the name as text to find namesakes too.

Research ArticleOpen accessEffect of Length Ratios on Heat Transfer Characteristics of Closed-Loop Oscillating Heat Pipe with Non-Uniform DiameterP. Sakulchangsatjatai, P. Pathike, P. TerdtoonProblem statement: Closed-loop oscillating heat pipe is a high performance heat exchanger especially as this heat exchanger has one direction flow of working fluid inside tube. Approach: This research studies the effect of length ratios on heat transfer characteristic of Closed Loop Oscillating Heat Pipe with Non-Uniform Diameter (CLOHP/NUD). The 2.03 and 1.06 mm inner diameter of capillary tube were … …Energy Research Journal, Vol. 1, Issue 2 · 31 Oct 2010 · 7,680 accessesView PDFCite
Research ArticleOpen accessStress-Strain Analysis of Abdominal Aortic Wall: A Case of 3D Geometry SimulationP. Khamdaengyodtai, P. Sakulchangsatjatai, P. TerdtoonProblem statement: This study analyzed stress-strain of abdominal aortic wall in 3D geometry simulation. Abdominal aorta is a portion of the aorta vessel in the abdomen which many cardiovascular diseases often occur. Approach: Abdominal aortic wall was considered as 1 layers-3 dimensional cylindrical geometry and homogeneous, incompressible and anisotropic material. Deformation of aortic wall was elastic deformation. Numerical method was … …Energy Research Journal, Vol. 1, Issue 2 · 31 Oct 2010 · 7,406 accessesView PDFCite
Research ArticleOpen accessMathematical Model of the Optimum Heat Pipe Heat Exchanger for a Condenser of Vapor-Compression Refrigeration CycleP. Yeunyongkul, P. Sakulchangsatjatai, P. TerdtoonProblem statement: This study theoretically investigated applying heat pipe as a heat exchanger in the condenser of vapor compression refrigeration system for sustainable well-being. Split-type air conditioner for residential propose was considered. To reduce pressure drop and recover heat from the condensing process of the refrigeration cycle, this investigation tried to use Closed Loop Oscillating Heat Pipe (CLOHP) instead of … …Energy Research Journal, Vol. 1, Issue 2 · 31 Oct 2010 · 8,631 accessesView PDFCite
Research ArticleOpen accessEffects of Aspect Ratios and Number of Meandering Turns on Performance Limit of an Inclined Closed-Loop Oscillating Heat PipeN. Panyoyai, P. Terdtoon, P. SakulchangsatjataiProblem statement: The purpose of this research was to determine the effects of aspect ratios and number of meandering turns on performance limit of an inclined closed-loop oscillating heat pipe. Approach: The Closed-Loop Oscillating Heat Pipe (CLOHP) was made of a long copper capillary tube. The geometrical sizes, which were the variable parameters of this study, were as follows; the … …Energy Research Journal, Vol. 1, Issue 2 · 31 Oct 2010 · 8,081 accessesView PDFCite
Research ArticleOpen accessEffect of Inclination Angle on Performance Limit of a Closed-End Oscillating Heat PipeT. Hudakorn, P. Terdtoon, P. SakulchangsatjataiThis study presents the effect of inclination angle on the performance limit of a Closed-End Oscillating Heat Pipe (CEOHP). The study was divided into 2 corresponding parts. The first part was visual study. The CEOHP was made of Pyrex glass tube with the inner diameter of 1.0 mm, evaporator length of 50 mm and had 10 meandering turns. The lengths … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 3 · 30 Sep 2008 · 7,516 accessesView PDFCite
Research ArticleOpen accessEffect of Evaporator Lengths and Ratio of Check Valves to Number of Turns on Internal Flow Patterns of a Closed-Loop Oscillating Heat-Pipe With Check ValvesS. Rittidech, P. Meena, P. TerdtoonA visualization study of the internal flow patterns of a closed-loop oscillating heat-pipe with check valves (CLOHP/CV) at normal operating condition for several evaporator lengths (Le), and ratio of check valves to number of turns (Rcv) has been conducted. This article describes the effects of varying Le, and Rcv on flow patterns. The CLOHP/CV used a Pyrex glass tube with … …American Journal of Applied Sciences, Vol. 5, Issue 3 · 31 Mar 2008 · 7,266 accessesView PDFCite