Sign inSubmit
Tips: “quotes” for a phrase · author:Lee · a DOI goes straight to its article
Author

S. Rittidech

8 articles in our journals

Articles where this person is an author, newest first. People are matched by their name as printed (no ORCID iD is recorded for them), not by name alone; search the name as text to find namesakes too.

Research ArticleOpen accessEffect of Evaporator Section Lengths and Working Fluids on Operational Limit of Closed Loop Oscillating Heat Pipes with Check Valves (CLOHP/CV)P. Meena, S. Rittidech, P. TammasaengThis research aims to the effect of evaporator section lengths and working fluids on operational limit of closed loop oscillating heat pipes with check valves (CLOHP/CV) with R123 Ethanol and Water were used as the working fluids. A set of CLOHP/CV was made of copper tubes in combination of following dimension: 1.77 mm inside diameter: 10 turns: 5, 10 and … …American Journal of Applied Sciences, Vol. 6, Issue 1 · 31 Jan 2009 · 7,779 accessesView PDFCite
Research ArticleOpen accessWaste Heat Recovery by Closed-Loop Oscillating Heat Pipe with Check Valve from Pottery Kilns for Energy ThriftP. Meena, S. RittidechThis study aims to design, construct and test the waste heat recovery by closed-loop oscillating heat pipe with check valve from pottery kilns for energy thrift, were used the working fluids with a filling ratio of 50%. The (CLOHO/CV) was made of copper capillary tube with inside diameter of 2.03 mm. The lengths of evaporator and condenser section were 20 … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 2 · 30 Jun 2008 · 7,497 accessesView PDFCite
Research ArticleOpen accessEffect of Inner Diameter and Inclination Angles on Operation Limit of Closed-Loop Oscillating Heat-Pipes with Check ValvesP. Meena, S. Rittidech, P. TammasaengThis research was to study the effect of inner diameter and inclination angles on operation limit of a closed loop oscillating heat pipes with check valves (CLOHP/CV). A set of CLOHP/CV was made of copper tubes in combination of following dimension: 1.77 and 2.03 mm inside diameter: 10 turn, with R123 was used as the working fluid. The working fluid … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 2 · 30 Jun 2008 · 7,153 accessesView PDFCite
Research ArticleOpen accessComparisons of Heat Transfer Performance of a Closed-looped Oscillating Heat Pipe and Closed-looped Oscillating Heat Pipe with Check Valves Heat ExchangersP. Meena, S. RittidechThis research was to study the comparisons of heat transfer performance of closed-looped oscillating heat pipe and closed-looped oscillating heat pipe with check valves heat exchangers with R134a, Ethanol and water were used as the working fluids. A set of heat pipe heat exchanger (CLOHP and CLOHP/CV) were made of copper tubes in combination of following dimension: 2.03 mm inside … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 1 · 31 Mar 2008 · 7,496 accessesView PDFCite
Research ArticleOpen accessEffect of Evaporator Lengths and Ratio of Check Valves to Number of Turns on Internal Flow Patterns of a Closed-Loop Oscillating Heat-Pipe With Check ValvesS. Rittidech, P. Meena, P. TerdtoonA visualization study of the internal flow patterns of a closed-loop oscillating heat-pipe with check valves (CLOHP/CV) at normal operating condition for several evaporator lengths (Le), and ratio of check valves to number of turns (Rcv) has been conducted. This article describes the effects of varying Le, and Rcv on flow patterns. The CLOHP/CV used a Pyrex glass tube with … …American Journal of Applied Sciences, Vol. 5, Issue 3 · 31 Mar 2008 · 7,274 accessesView PDFCite
Research ArticleOpen accessEffect of Internal Flow Patterns on Heat transfer Performance of a Closed-end Oscillating Heat Pipe at Vertical PositionS. Rittidech, L. Yodluk, K. SongsornThis article describes the effects of varying bond numbers (Bo) and aspect ratios (Le/d) on flow pattern of a close-end oscillating heat-pipe (CEOHP). The CEOHPs used employed a glass tube with inside diameter of 3 mm. The length of evaporator of 100 and 150 mm (the lengths of evaporator adiabatic and condenser section were equal) were employed with 10 turns. … …American Journal of Applied Sciences, Vol. 4, Issue 12 · 31 Dec 2007 · 7,064 accessesView PDFCite
Research ArticleOpen accessCPU Cooling of Desktop PC by Closed-end Oscillating Heat-pipe (CEOHP)S. Rittidech, A. Boonyaem, P. TipnetThe CEOHP cooling module consisted of two main parts, i.e., the aluminum housing and the CEOHP. The house casing was designed to be suitable for CEOHP. The housing to drilling for insert the CEOHP. The CEOHP design employed copper tubes: Two sets of capillary tubes with an inner diameter of 0.002 m, an evaporator length of 0.05 and a condenser … …American Journal of Applied Sciences, Vol. 2, Issue 12 · 31 Dec 2005 · 8,456 accessesView PDFCite
Research ArticleOpen accessEffect of Geometry and Dimensionless Parameters on Heat Transfer Characteristics of a Closed–end Oscillating Heat-pipe at Vertical PositionS. Rittidech, K. PhalasinThis heat transfer characteristics of a closed-end oscillating heat-pipe (CEOHP) depend on a number of parameters. They are the number of turns, inner diameter of the tube, aspect ratio and the dimensionless parameters of heat transfer. The CEOHPs used to employ a copper tube with inner diameter of 0.66, 1.09 and 2.03 mm. The lengths of the evaporator, adiabatic and … …American Journal of Applied Sciences, Vol. 2, Issue 11 · 30 Nov 2005 · 6,646 accessesView PDFCite