Sign inSubmit
Tips: “quotes” for a phrase · author:Lee · a DOI goes straight to its article

7 results for “copper tubes”

Set a search alert
Research ArticleOpen accessIn the keywordsEffect of Inner Diameter and Inclination Angles on Operation Limit of Closed-Loop Oscillating Heat-Pipes with Check ValvesP. Meena, S. Rittidech, P. TammasaengThis research was to study the effect of inner diameter and inclination angles on operation limit of a closed loop oscillating heat pipes with check valves (CLOHP/CV). A set of CLOHP/CV was made of copper tubes in combination of following dimension: 1.77 and 2.03 mm inside diameter: 10 turn, with R123 was used as the working fluid. The working fluid … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 2 · 30 Jun 2008 · 7,145 accessesView PDFCite
Research ArticleOpen accessIn the abstractSolar Water Desalination System with Condenser Without Using Electricity for Rural AreasAbhijeet Auti, Tejinder Singh, Dilip Pangavhane, Ashok ChavanDomestic desalination is a process in which salt water is heated and converted to steam by using parabolic solar concentrator. Solar radiations incident on concentrator are focused at the absorber which contains salt water. The steam is then condensed by the condenser which is designed on the basis of the thermal analysis. Condenser is a basically a water tank with … …American Journal of Applied Sciences, Vol. 10, Issue 9 · 24 Aug 2013 · 6,903 accessesView PDFCite
Research ArticleOpen accessIn the abstractApplied a Closed-Loop Oscillating Heat-Pipe Heat Exchanger to Increasing Oil Yield in Pyrolysis ProcessN. Panyoyai, T. Wongsiriamnuay, S. SangsrichanProblem statement: A Closed-Loop Oscillating Heat-Pipe (CLOHP) heat exchanger was a heat exchanger with one of the most promising conductivity capacities because of its higher cooling and condensing potential. Therefore, the aims of this study were to design and fabricate a CLOHP to be applied to increasing oil yield in the pyrolysis process. Approach: Two types of oscillating heat-pipe arrangements-parallel … …Energy Research Journal, Vol. 1, Issue 1 · 30 Jun 2010 · 7,620 accessesView PDFCite
Research ArticleOpen accessIn the abstractEffect of Evaporator Section Lengths and Working Fluids on Operational Limit of Closed Loop Oscillating Heat Pipes with Check Valves (CLOHP/CV)P. Meena, S. Rittidech, P. TammasaengThis research aims to the effect of evaporator section lengths and working fluids on operational limit of closed loop oscillating heat pipes with check valves (CLOHP/CV) with R123 Ethanol and Water were used as the working fluids. A set of CLOHP/CV was made of copper tubes in combination of following dimension: 1.77 mm inside diameter: 10 turns: 5, 10 and … …American Journal of Applied Sciences, Vol. 6, Issue 1 · 31 Jan 2009 · 7,776 accessesView PDFCite
Research ArticleOpen accessIn the abstractEffect of Inclination Angle on Performance Limit of a Closed-End Oscillating Heat PipeT. Hudakorn, P. Terdtoon, P. SakulchangsatjataiThis study presents the effect of inclination angle on the performance limit of a Closed-End Oscillating Heat Pipe (CEOHP). The study was divided into 2 corresponding parts. The first part was visual study. The CEOHP was made of Pyrex glass tube with the inner diameter of 1.0 mm, evaporator length of 50 mm and had 10 meandering turns. The lengths … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 3 · 30 Sep 2008 · 7,516 accessesView PDFCite
Research ArticleOpen accessIn the abstractComparisons of Heat Transfer Performance of a Closed-looped Oscillating Heat Pipe and Closed-looped Oscillating Heat Pipe with Check Valves Heat ExchangersP. Meena, S. RittidechThis research was to study the comparisons of heat transfer performance of closed-looped oscillating heat pipe and closed-looped oscillating heat pipe with check valves heat exchangers with R134a, Ethanol and water were used as the working fluids. A set of heat pipe heat exchanger (CLOHP and CLOHP/CV) were made of copper tubes in combination of following dimension: 2.03 mm inside … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 1 · 31 Mar 2008 · 7,492 accessesView PDFCite
Research ArticleOpen accessIn the abstractCPU Cooling of Desktop PC by Closed-end Oscillating Heat-pipe (CEOHP)S. Rittidech, A. Boonyaem, P. TipnetThe CEOHP cooling module consisted of two main parts, i.e., the aluminum housing and the CEOHP. The house casing was designed to be suitable for CEOHP. The housing to drilling for insert the CEOHP. The CEOHP design employed copper tubes: Two sets of capillary tubes with an inner diameter of 0.002 m, an evaporator length of 0.05 and a condenser … …American Journal of Applied Sciences, Vol. 2, Issue 12 · 31 Dec 2005 · 8,454 accessesView PDFCite