Sign inSubmit
Tips: “quotes” for a phrase · author:Lee · a DOI goes straight to its article

155 articles for “pipe”

Set a search alert
Research ArticleOpen accessEvery word in the titleWaste Heat Recovery by Closed-Loop Oscillating Heat Pipe with Check Valve from Pottery Kilns for Energy ThriftP. Meena, S. RittidechThis study aims to design, construct and test the waste heat recovery by closed-loop oscillating heat pipe with check valve from pottery kilns for energy thrift, were used the working fluids with a filling ratio of 50%. The (CLOHO/CV) was made of copper capillary tube with inside diameter of 2.03 mm. The lengths of evaporator and condenser section were 20 … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 2 · 30 Jun 2008 · 7,490 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleComparisons of Heat Transfer Performance of a Closed-looped Oscillating Heat Pipe and Closed-looped Oscillating Heat Pipe with Check Valves Heat ExchangersP. Meena, S. RittidechThis research was to study the comparisons of heat transfer performance of closed-looped oscillating heat pipe and closed-looped oscillating heat pipe with check valves heat exchangers with R134a, Ethanol and water were used as the working fluids. A set of heat pipe heat exchanger (CLOHP and CLOHP/CV) were made of copper tubes in combination of following dimension: 2.03 mm inside … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 1 · 31 Mar 2008 · 7,492 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleEffect of Evaporator Lengths and Ratio of Check Valves to Number of Turns on Internal Flow Patterns of a Closed-Loop Oscillating Heat-Pipe With Check ValvesS. Rittidech, P. Meena, P. TerdtoonA visualization study of the internal flow patterns of a closed-loop oscillating heat-pipe with check valves (CLOHP/CV) at normal operating condition for several evaporator lengths (Le), and ratio of check valves to number of turns (Rcv) has been conducted. This article describes the effects of varying Le, and Rcv on flow patterns. The CLOHP/CV used a Pyrex glass tube with … …American Journal of Applied Sciences, Vol. 5, Issue 3 · 31 Mar 2008 · 7,266 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleEffect of Internal Flow Patterns on Heat transfer Performance of a Closed-end Oscillating Heat Pipe at Vertical PositionS. Rittidech, L. Yodluk, K. SongsornThis article describes the effects of varying bond numbers (Bo) and aspect ratios (Le/d) on flow pattern of a close-end oscillating heat-pipe (CEOHP). The CEOHPs used employed a glass tube with inside diameter of 3 mm. The length of evaporator of 100 and 150 mm (the lengths of evaporator adiabatic and condenser section were equal) were employed with 10 turns. … …American Journal of Applied Sciences, Vol. 4, Issue 12 · 31 Dec 2007 · 7,062 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleInvestigation on the Behavior of Rigid Polyvinylchloride Pipes Subjected to Uniaxial Compression LoadsAbdullah Ali Nasser Alhamati, Abdul Halim Ghazali, Jamalodin Norzaie et al.The objective of this research was to investigate the capability of rigid Polyvinylchloride (PVC-U) pipes to sustain axial loads. The behavior of PVC-U pipes specimens subjected to short-term uniaxial compression loads was experimentally investigated. Results of the load-displacement tests on pipes of different wall thickness, diameter and specimen heights were recorded. The experimental test results show that the PVC-U pipes … …American Journal of Applied Sciences, Vol. 3, Issue 7 · 31 Jul 2006 · 6,696 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleEffect of Geometry and Dimensionless Parameters on Heat Transfer Characteristics of a Closed–end Oscillating Heat-pipe at Vertical PositionS. Rittidech, K. PhalasinThis heat transfer characteristics of a closed-end oscillating heat-pipe (CEOHP) depend on a number of parameters. They are the number of turns, inner diameter of the tube, aspect ratio and the dimensionless parameters of heat transfer. The CEOHPs used to employ a copper tube with inner diameter of 0.66, 1.09 and 2.03 mm. The lengths of the evaporator, adiabatic and … …American Journal of Applied Sciences, Vol. 2, Issue 11 · 30 Nov 2005 · 6,642 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleRoughness Effect on an Unsteady Flow in Pipelines by Profilometry and Imaging TechniquesMabrouk Benkhedimallah, Rabah Zegadi, Mohamed BouafiaProblem statement: Currently the aero dynamical calculation in gas pipes is carried out under the assumption of steady state conditions. However real steady in a network is scarcely quasisteady. Approach: The unsteady state is governed by non-linear partial differential equations leading to mathematical difficulties. And there are fore gas pipe dimensions are computed at steady state under extreme conditions. Results: … …American Journal of Engineering and Applied Sciences, Vol. 4, Issue 1 · 29 Jan 2011 · 8,152 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleA Cheap Aerial Gas PipelineAlexander A. BolonkinProblem statement: At present time gas pipelines are designed from steel and located on ground surface. That is very expensive and building requests a lot of time. Research and utilization of an old author idea: Design of new cheap aerial pipelines, a large flexible tube deployed at high altitude through neutral seas, for delivery of natural (fuel) gas, water and … …American Journal of Engineering and Applied Sciences, Vol. 2, Issue 4 · 31 Dec 2009 · 7,294 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleEffect of Evaporator Section Lengths and Working Fluids on Operational Limit of Closed Loop Oscillating Heat Pipes with Check Valves (CLOHP/CV)P. Meena, S. Rittidech, P. TammasaengThis research aims to the effect of evaporator section lengths and working fluids on operational limit of closed loop oscillating heat pipes with check valves (CLOHP/CV) with R123 Ethanol and Water were used as the working fluids. A set of CLOHP/CV was made of copper tubes in combination of following dimension: 1.77 mm inside diameter: 10 turns: 5, 10 and … …American Journal of Applied Sciences, Vol. 6, Issue 1 · 31 Jan 2009 · 7,776 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleEffect of Inner Diameter and Inclination Angles on Operation Limit of Closed-Loop Oscillating Heat-Pipes with Check ValvesP. Meena, S. Rittidech, P. TammasaengThis research was to study the effect of inner diameter and inclination angles on operation limit of a closed loop oscillating heat pipes with check valves (CLOHP/CV). A set of CLOHP/CV was made of copper tubes in combination of following dimension: 1.77 and 2.03 mm inside diameter: 10 turn, with R123 was used as the working fluid. The working fluid … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 2 · 30 Jun 2008 · 7,145 accessesView PDFCite