Sign inSubmit
Tips: “quotes” for a phrase · author:Lee · a DOI goes straight to its article

4 results for “Closed-looped oscillating heat-pipe”

Set a search alert
Research ArticleOpen accessEvery word in the titleComparisons of Heat Transfer Performance of a Closed-looped Oscillating Heat Pipe and Closed-looped Oscillating Heat Pipe with Check Valves Heat ExchangersP. Meena, S. RittidechThis research was to study the comparisons of heat transfer performance of closed-looped oscillating heat pipe and closed-looped oscillating heat pipe with check valves heat exchangers with R134a, Ethanol and water were used as the working fluids. A set of heat pipe heat exchanger (CLOHP and CLOHP/CV) were made of copper tubes in combination of following dimension: 2.03 mm inside … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 1 · 31 Mar 2008 · 7,492 accessesView PDFCite
Research ArticleOpen accessIn the keywordsEffect of Evaporator Section Lengths and Working Fluids on Operational Limit of Closed Loop Oscillating Heat Pipes with Check Valves (CLOHP/CV)P. Meena, S. Rittidech, P. TammasaengThis research aims to the effect of evaporator section lengths and working fluids on operational limit of closed loop oscillating heat pipes with check valves (CLOHP/CV) with R123 Ethanol and Water were used as the working fluids. A set of CLOHP/CV was made of copper tubes in combination of following dimension: 1.77 mm inside diameter: 10 turns: 5, 10 and … …American Journal of Applied Sciences, Vol. 6, Issue 1 · 31 Jan 2009 · 7,776 accessesView PDFCite
Research ArticleOpen accessIn the keywordsWaste Heat Recovery by Closed-Loop Oscillating Heat Pipe with Check Valve from Pottery Kilns for Energy ThriftP. Meena, S. RittidechThis study aims to design, construct and test the waste heat recovery by closed-loop oscillating heat pipe with check valve from pottery kilns for energy thrift, were used the working fluids with a filling ratio of 50%. The (CLOHO/CV) was made of copper capillary tube with inside diameter of 2.03 mm. The lengths of evaporator and condenser section were 20 … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 2 · 30 Jun 2008 · 7,490 accessesView PDFCite
Research ArticleOpen accessIn the keywordsEffect of Inner Diameter and Inclination Angles on Operation Limit of Closed-Loop Oscillating Heat-Pipes with Check ValvesP. Meena, S. Rittidech, P. TammasaengThis research was to study the effect of inner diameter and inclination angles on operation limit of a closed loop oscillating heat pipes with check valves (CLOHP/CV). A set of CLOHP/CV was made of copper tubes in combination of following dimension: 1.77 and 2.03 mm inside diameter: 10 turn, with R123 was used as the working fluid. The working fluid … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 2 · 30 Jun 2008 · 7,145 accessesView PDFCite