Sign inSubmit
Tips: “quotes” for a phrase · author:Lee · a DOI goes straight to its article

593 articles for “close”

Set a search alert
Research ArticleOpen accessEvery word in the titleEffect of Internal Flow Patterns on Heat transfer Performance of a Closed-end Oscillating Heat Pipe at Vertical PositionS. Rittidech, L. Yodluk, K. SongsornThis article describes the effects of varying bond numbers (Bo) and aspect ratios (Le/d) on flow pattern of a close-end oscillating heat-pipe (CEOHP). The CEOHPs used employed a glass tube with inside diameter of 3 mm. The length of evaporator of 100 and 150 mm (the lengths of evaporator adiabatic and condenser section were equal) were employed with 10 turns. … …American Journal of Applied Sciences, Vol. 4, Issue 12 · 31 Dec 2007 · 7,062 accessesView PDFCite
Research ArticleOpen accessEvery word in the title3-DIMENSIONAL EAR RECOGNITION BASED ITERATIVE CLOSEST POINT WITH STOCHASTIC CLUSTERING MATCHINGKhamiss Masaoud S. Algabary, Khairuddin Omar, Md Jan NordinEar recognition is a new technology and future trend for personal identification. However, the false detection rate and matching recognition are very challenging due to the ear complex geometry. The Scope of the study is to introduced a combination of Iterative Closest Point (ICP) and Stochastic Clustering Matching (SCM) algorithm for 3D ears matching based on biometrics field with a … …Journal of Computer Science, Vol. 10, Issue 3 · 29 Nov 2013 · 6,812 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleU.S. Malpractice in Internal Medicine: Closed Claim Cases as Tools for Identification, Teaching and PreventionKimberly Ku, Theresa Vettese, Diane LevineMedical malpractice litigation as a system in the U.S. serves multiple goals, including the promotion of safer medicine and the compensation of wrongfully injured patients. However, these aims are often at odds with systems-oriented strategies needed to promote patient safety. Additionally, there is widespread doubt of the actual fairness and efficiency of malpractice litigation. Regardless of the details surrounding major … …Current Research in Medicine, Vol. 4, Issue 2 · 4 Sep 2013 · 6,989 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleEffect of Length Ratios on Heat Transfer Characteristics of Closed-Loop Oscillating Heat Pipe with Non-Uniform DiameterP. Sakulchangsatjatai, P. Pathike, P. TerdtoonProblem statement: Closed-loop oscillating heat pipe is a high performance heat exchanger especially as this heat exchanger has one direction flow of working fluid inside tube. Approach: This research studies the effect of length ratios on heat transfer characteristic of Closed Loop Oscillating Heat Pipe with Non-Uniform Diameter (CLOHP/NUD). The 2.03 and 1.06 mm inner diameter of capillary tube were … …Energy Research Journal, Vol. 1, Issue 2 · 31 Oct 2010 · 7,680 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleEstablishment, Verification and Application of a Correlation to Predict the Maximum Heat Flux of a Horizontal Closed-Loop Pulsating Heat PipeNiti Kammuang-Lue, Teerasak Hudakorn, Pradit TerdtoonProblem statement: In heat pipe design, it was very important to be sure that the desired heat pipe would not operate in the MHF state. In the case of a vertical CLPHP, the MHF state and maximum heat flux could be predicted by using the correlation, while, in the case of a horizontal CLPHP, there had been no study presented … …Energy Research Journal, Vol. 1, Issue 2 · 31 Oct 2010 · 7,422 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleEffects of Aspect Ratios and Number of Meandering Turns on Performance Limit of an Inclined Closed-Loop Oscillating Heat PipeN. Panyoyai, P. Terdtoon, P. SakulchangsatjataiProblem statement: The purpose of this research was to determine the effects of aspect ratios and number of meandering turns on performance limit of an inclined closed-loop oscillating heat pipe. Approach: The Closed-Loop Oscillating Heat Pipe (CLOHP) was made of a long copper capillary tube. The geometrical sizes, which were the variable parameters of this study, were as follows; the … …Energy Research Journal, Vol. 1, Issue 2 · 31 Oct 2010 · 8,081 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleSequences of Closed Operators and CorrectnessSabra Ramadan, Abdulla Al-HossainIn applications and in mathematical physics equations it is very important for mathematical models corresponding to the given problem to be correct given. In this research we will study the relationship between the sequence of closed operators An→A and the correctness of the equation Ax = y. Also we will introduce the criterion for correctness. …American Journal of Applied Sciences, Vol. 7, Issue 3 · 31 Mar 2010 · 7,291 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleGreatest Common Divisor and Least Common Multiple Matrices on Factor Closed Sets in a Principal Ideal DomainA. N. El-Kassar, S. S. Habre, Y. A. AwadProblem statement: Let T be a set of n distinct positive integers, x1, x2, ..., xn. The n×n matrix [T] having (xi, xj), the greatest common divisor of xi and xj, as its (i,j)-entry is called the greatest common divisor (GCD) matrix on T. The matrix [[T]] whose (i,j)-entry is [xi, xj], the least common multiple of xi and xj, … …Journal of Mathematics and Statistics, Vol. 5, Issue 4 · 31 Dec 2009 · 8,379 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleEffect of Evaporator Section Lengths and Working Fluids on Operational Limit of Closed Loop Oscillating Heat Pipes with Check Valves (CLOHP/CV)P. Meena, S. Rittidech, P. TammasaengThis research aims to the effect of evaporator section lengths and working fluids on operational limit of closed loop oscillating heat pipes with check valves (CLOHP/CV) with R123 Ethanol and Water were used as the working fluids. A set of CLOHP/CV was made of copper tubes in combination of following dimension: 1.77 mm inside diameter: 10 turns: 5, 10 and … …American Journal of Applied Sciences, Vol. 6, Issue 1 · 31 Jan 2009 · 7,776 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleEffect of Inclination Angle on Performance Limit of a Closed-End Oscillating Heat PipeT. Hudakorn, P. Terdtoon, P. SakulchangsatjataiThis study presents the effect of inclination angle on the performance limit of a Closed-End Oscillating Heat Pipe (CEOHP). The study was divided into 2 corresponding parts. The first part was visual study. The CEOHP was made of Pyrex glass tube with the inner diameter of 1.0 mm, evaporator length of 50 mm and had 10 meandering turns. The lengths … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 3 · 30 Sep 2008 · 7,516 accessesView PDFCite