Research ArticleOpen accessPhrase in the titleFuzzy Logic Controller Based Three-phase Shunt Active Filter for Line Harmonics ReductionC. Sharmeela, M. R. Mohan, G. Uma, J. BaskaranHarmonic distortion is a form of electrical noise. It is a superposition of signals, which are of multiples of fundamental frequency. Proliferation of large power electronic systems results in increased harmonic distortion. Harmonic distortion results in reduction of power quality and system stability. This paper presents fuzzy control applicable for active power filter for three-phase systems, which are comprised of … …Journal of Computer Science, Vol. 3, Issue 2 · 28 Feb 2007 · 7,107 accessesView PDFCite
Research ArticleOpen accessIn the keywordsHarmonics Study and Comparison of Z-source Inverter with Traditional InvertersB. Justus Rabi, R. ArumugamThis paper presents an Impedance Source Inverter for A.C electrical drives. The impedance source inverter employs a unique impedance network cable with inverter main circuit and rectifier. By controlling the shoot-through duty cycle, the z-source inverter system using MOSFETS provide ride-through capability during voltage sags, reduces line harmonics, improves power factor and high reliability, and extends output voltage range. Analysis, … …American Journal of Applied Sciences, Vol. 2, Issue 10 · 31 Oct 2005 · 7,281 accessesView PDFCite
Research ArticleOpen accessIn the abstractQuality Measurements on the Radio Interface of the Mobile Communication in the Proximity of the Power SystemSaid Ghnimi, Adnen Rajhi, Ali Gharsallah, Fakhreddine KhlifaProblem statement: The electric power lines and its associated equipments generally produce an electromagnetic noise in their environment, which are likely to have dangerous effects on propagation environment to the Global System for Mobile communication (GSM) cellular mobile network. Approach: In this study, we analyzed the characteristics of the power line noise and its correlation with the GSM burst; showing … …American Journal of Applied Sciences, Vol. 8, Issue 5 · 26 Mar 2015 · 7,000 accessesView PDFCite
Research ArticleOpen accessIn the abstractSimulation Analysis on Proportional Integral and Derivative Control of Closed Loop DC Motor Drive with Bipolar Voltage SwitchingP. Karpagavalli, A. Ebenezer JeyakumarThis study presents the performance of a new four quadrant single phase DC drive closed loop system controlled by proportional integral and derivative controller with Pulse Width Modulation (PWM) full bridge DC-DC converter using bipolar voltage switching. The proposed method is found to be more efficient in improving the step response characteristics such as reducing the settling time, rise time, … …American Journal of Applied Sciences, Vol. 10, Issue 7 · 29 Jun 2013 · 6,908 accessesView PDFCite
Research ArticleOpen accessIn the abstractControl Strategy for Discontinuous Conduction Mode Boost Rectifier with Low Total Harmonic Distortion and Improved Dynamic ResponseH.S. AthabDue to its simplicity, the discontinuous conduction mode boost rectifier is potentially the least expensive active line-harmonics reducing circuit. Problem statement: The line current however, shows considerable distortion when the peak input voltage is close to the output voltage, As a result, the input power factor is poor. This study proposes a simple, low-cost method to reduce the line harmonics. … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 4 · 31 Dec 2008 · 7,418 accessesView PDFCite
Research ArticleOpen accessIn the abstractThe Effects of Harmonic Components on Transformer Losses of Sinusoidal Source Supplying Non-Linear LoadsI. Daut, H. S. Syafruddin, Rosnazri Ali et al.An important consideration when evaluating the impact of harmonics is their effect on power system component and loads. Transformers are major components in power systems. The increased losses due to harmonic distortion can cause excessive losses and hence abnormal temperature rise. The measurement of iron losses and copper losses of single-phase transformers is important in particular for transformers feeding nonlinear … …American Journal of Applied Sciences, Vol. 3, Issue 12 · 31 Dec 2006 · 8,398 accessesView PDFCite
Research ArticleOpen accessIn the abstractA Low Cost Design Solution - DSP Based Active Power Factor Corrector for SMPS/ UPS( Single Phase)Samia Pillai Pitchai, B. UmamaheswariAs per international agency regulation (IEC 1000-3-2/EN 61000-3-2) and market expectation, it is important to reduce current harmonics in the AC line current drawn by SMPS/ UPS connected to AC Mains as source and also it is desired by the user to deliver maximum power output by achieving unity power factor. To achieve the above objectives in SMPS/ UPS, APFC … …American Journal of Applied Sciences, Vol. 3, Issue 1 · 31 Jan 2006 · 6,896 accessesView PDFCite
Research ArticleOpen accessAll words, across the recordImplementation of a Novel Control Strategy Using Fuzzy Logic Controller to Shunt Active Filter for Line Harmonic ReductionN. Senthilnathan, T. ManigandanProblem statement: Now days, power quality has been given attention due to the intensive use of power electronic equipments in all types of industries such as steel, paper, textile industries and so on. These power electronic devices induce harmonic distortion into the supply lines which gives rise to many undesirable effects. Approach: This study presents a new method for harmonic … …Journal of Computer Science, Vol. 8, Issue 5 · 29 Feb 2012 · 7,087 accessesView PDFCite