Sign inSubmit
ArticleArticle metrics
Research Article · Free to read · Published 31 December 2006

The Effects of Harmonic Components on Transformer Losses of Sinusoidal Source Supplying Non-Linear Loads

I. Daut, H. S. Syafruddin, Rosnazri Ali, M.D. Samila & H. Haziah

American Journal of Applied Sciences, Volume 3, Issue 12, pp. 2131–2133 · doi.org/10.3844/ajassp.2006.2131.2133

8,398 accesses7,285 downloads28 citations (Crossref)Journal metrics
Cite Check for updates

Abstract

An important consideration when evaluating the impact of harmonics is their effect on power system component and loads. Transformers are major components in power systems. The increased losses due to harmonic distortion can cause excessive losses and hence abnormal temperature rise. The measurement of iron losses and copper losses of single-phase transformers is important in particular for transformers feeding nonlinear loads. In computing of transformer losses, it is assumed that source voltage is sinusoidal and load impedance is linear. This study presents the effects of harmonic distortion of load current and voltage on single-phase transformer losses utilizing the on-line measurements (monitoring) method of the primary side. The transformer is loaded with an SCR speed controller that consists of a single-phase full-bridge rectifier, SCR and a resistant load to generate various total harmonic current and voltage distortions (THDi and THDv) conditions.

Licence and reuse

Free to read. This article carries the publisher’s copyright, as printed on it: © 2006 Science Publications. It is free to read; ask us before reusing it.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Daut, I., Syafruddin, H. S., Ali, R., Samila, M. & Haziah, H. (2006). The Effects of Harmonic Components on Transformer Losses of Sinusoidal Source Supplying Non-Linear Loads . American Journal of Applied Sciences, 3(12), 2131–2133. https://doi.org/10.3844/ajassp.2006.2131.2133

Licence
© Science Publications
Issue
Volume 3, Issue 12
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
The Effects of Harmonic Components on Transformer Losses of Sinusoidal Source Supplying Non-Linear LoadsAmerican Journal of Applied Sciences · Volume 3, Issue 12 · pp. 2131–2133 · © Science PublicationsDownload