Sign inSubmit
Tips: “quotes” for a phrase · author:Lee · a DOI goes straight to its article

6 articles for “Heat pipe heat exchanger”

Set a search alert
Research ArticleOpen accessPhrase in the titleMathematical Model of the Optimum Heat Pipe Heat Exchanger for a Condenser of Vapor-Compression Refrigeration CycleP. Yeunyongkul, P. Sakulchangsatjatai, P. TerdtoonProblem statement: This study theoretically investigated applying heat pipe as a heat exchanger in the condenser of vapor compression refrigeration system for sustainable well-being. Split-type air conditioner for residential propose was considered. To reduce pressure drop and recover heat from the condensing process of the refrigeration cycle, this investigation tried to use Closed Loop Oscillating Heat Pipe (CLOHP) instead of … …Energy Research Journal, Vol. 1, Issue 2 · 31 Oct 2010 · 8,631 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleApplied a Closed-Loop Oscillating Heat-Pipe Heat Exchanger to Increasing Oil Yield in Pyrolysis ProcessN. Panyoyai, T. Wongsiriamnuay, S. SangsrichanProblem statement: A Closed-Loop Oscillating Heat-Pipe (CLOHP) heat exchanger was a heat exchanger with one of the most promising conductivity capacities because of its higher cooling and condensing potential. Therefore, the aims of this study were to design and fabricate a CLOHP to be applied to increasing oil yield in the pyrolysis process. Approach: Two types of oscillating heat-pipe arrangements-parallel … …Energy Research Journal, Vol. 1, Issue 1 · 30 Jun 2010 · 7,620 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleComparisons of Heat Transfer Performance of a Closed-looped Oscillating Heat Pipe and Closed-looped Oscillating Heat Pipe with Check Valves Heat ExchangersP. Meena, S. RittidechThis research was to study the comparisons of heat transfer performance of closed-looped oscillating heat pipe and closed-looped oscillating heat pipe with check valves heat exchangers with R134a, Ethanol and water were used as the working fluids. A set of heat pipe heat exchanger (CLOHP and CLOHP/CV) were made of copper tubes in combination of following dimension: 2.03 mm inside … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 1 · 31 Mar 2008 · 7,492 accessesView PDFCite
Research ArticleOpen accessIn the keywordsWaste Heat Recovery by Closed-Loop Oscillating Heat Pipe with Check Valve from Pottery Kilns for Energy ThriftP. Meena, S. RittidechThis study aims to design, construct and test the waste heat recovery by closed-loop oscillating heat pipe with check valve from pottery kilns for energy thrift, were used the working fluids with a filling ratio of 50%. The (CLOHO/CV) was made of copper capillary tube with inside diameter of 2.03 mm. The lengths of evaporator and condenser section were 20 … …American Journal of Engineering and Applied Sciences, Vol. 1, Issue 2 · 30 Jun 2008 · 7,490 accessesView PDFCite
Research ArticleOpen accessIn the abstractEffect of Exhaust Gas Temperature on the Performance of Automobile Adsorption Air-ConditionerAbdul Hadi N. Khalifa, Ali H. Jabbar, Jamal A. MuhsinAn adsorption air conditioning unit of two beds was designed and built. Each bed was constructed from two concentric copper pipes sets, the length of the pipes in each set was 1500 mm pipe. The inner pipe was 50 mm in diameter while the outer pipe was of 100 mm diameter. The inside surface of the outer pipe and the … …American Journal of Engineering and Applied Sciences, Vol. 8, Issue 4 · 13 Oct 2015 · 8,083 accessesView PDFCite
Research ArticleOpen accessIn the abstractEffect of Length Ratios on Heat Transfer Characteristics of Closed-Loop Oscillating Heat Pipe with Non-Uniform DiameterP. Sakulchangsatjatai, P. Pathike, P. TerdtoonProblem statement: Closed-loop oscillating heat pipe is a high performance heat exchanger especially as this heat exchanger has one direction flow of working fluid inside tube. Approach: This research studies the effect of length ratios on heat transfer characteristic of Closed Loop Oscillating Heat Pipe with Non-Uniform Diameter (CLOHP/NUD). The 2.03 and 1.06 mm inner diameter of capillary tube were … …Energy Research Journal, Vol. 1, Issue 2 · 31 Oct 2010 · 7,680 accessesView PDFCite