Sign inSubmit
Tips: “quotes” for a phrase · author:Lee · a DOI goes straight to its article

6 results for “post-tension”

Set a search alert
Research ArticleOpen accessPhrase in the titleFinite-Element Numerical Simulation of the Bending Performance of Post-Tensioned Structural Glass Beams with Adhesively Bonded CFRP TendonsChiara Bedon, Christian LouterIn this study, a Finite-Element (FE) numerical investigation is carried out on laminated glass beams with Carbon Fibre Reinforced Polymer (CFRP) adhesively bonded post-tensioning tendons. Taking advantage of past four-point bending experimental test results available in literature, a refined full 3D FE numerical model is calibrated and validated. A key role is given to a multitude of aspects, including the … …American Journal of Engineering and Applied Sciences, Vol. 9, Issue 3 · 27 Sep 2016 · 8,739 accessesView PDFCite
Research ArticleOpen accessPhrase in the titleShear Strength of Reinforced Concrete Beam Strengthened by Transverse External Post-tensionSayan Sirimontree, Boonsap Witchayangkoon, Nathavudh Khaosri, Jaruek TeerawongProblem statement: Shear failure of concrete beam is brittle manner without warning so inadequate design for shear of beam and/or material deterioration lead to the possibility of sudden failure of beam. The change of functional use and future increased load of structure lead to the need for strengthening of concrete structure. Approach: This research focuses on behaviors under static loading … …American Journal of Engineering and Applied Sciences, Vol. 4, Issue 1 · 31 Jan 2011 · 8,863 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleFlexural Behaviors of Damaged Full-Scale Highway Bridge Girder Strengthened by External Post TensionSayan Sirimontree, Jaruek TeerawongProblem statement: Prestressed Concrete (PC) I section girder with Reinforced Concrete (RC) topping slab has been widely applied to long span bridge girders for several years. A bridge girder is subjected to severe conditions caused by an aggressive environment and overloading. A crack can be initiated and propagate when the tensile stress exceeds the tensile strength of concrete due to … …American Journal of Engineering and Applied Sciences, Vol. 3, Issue 4 · 5 Nov 2010 · 8,670 accessesView PDFCite
Research ArticleOpen accessIn the keywordsHYGLASS: Design Proposal for an Integrated Multifunctional Hybrid Glass-Steel StructureMaurizio Froli, Francesco LacconeContemporary cities demand smart communication infrastructures to facilitate the interaction of residents and visitors with the urban environment. Such systems are required to be network-connected, interactive, environmental-sensitive and energetically self-sustaining. Moreover, in outdoor applications they should mark an urban focal point and should be able to satisfy additional public requirements like illumination, transmission of information etc. In the framework of … …International Journal of Structural Glass and Advanced Materials Research, Vol. 2, Issue 1 · 22 Jan 2018 · 7,254 accessesView PDFCite
Research ArticleOpen accessIn the abstractCalculation of the Hubble Constant, the Minimum Mass and the Proton Charge Radius Using the Dirac's Hypothesis on the Ratio of the Electrostatic Force to the Gravitational ForcePaul TalbotAtoui, M., Barbaro, M. B., Hoballah, M., Keyrouz, C., Lassaut, M., Marchand, D., Quéméner, G., & Voutier, E. (2023). Determination of the Moments of the Proton Charge Density. ArXiv, 13521. https://doi.org/10.48550/arXiv.2304.13521 Berman, M. S. (1992). Large Number Hypothesis. International Journal of Theoretical Physics, 31, 1447–1450. https://doi.org/10.1007/bf00673977 Beyer, A., Maisenbacher, L., Matveev, A., Pohl, R., Khabarova, K., Grinin, A., Lamour, T., … …Physics International, Vol. 14, Issue 1 · 2 Sep 2023 · 9,106 accessesView PDFCite
Research ArticleOpen accessIn the abstractPerformance of IBS Precast Concrete Beam-Column Connections Under Earthquake Effects: A Literature ReviewPatrick Tiong Liq Yee, Azlan Bin Adnan, Abdul Karim Mirasa, Ahmad Baharuddin Abdul RahmanProblem statement: Despite demonstrating rather much benefits comparing to the conventional cast-in-place construction, the acceptance level of precast concrete building is still reportedly low in Malaysia. The implication imposed by stricter seismic design provisions would only worsen the matter. Approach: The main objective of this study was to identify the most appropriate type of beam-column connections to be introduced to … …American Journal of Engineering and Applied Sciences, Vol. 4, Issue 1 · 31 Jan 2011 · 17,554 accessesView PDFCite