Research ArticleOpen accessEvery word in the titleNew Mersenne Number Transform Diffusion Power AnalysisM. F. Al-Gailani, S. BoussaktaProblem statement: Due to significant developments in the processing power and parallel processing technologies, the existing encryption algorithms are increasingly susceptible to attacks, such as side-channel attacks, for example. Designing new encryption algorithms that work efficiently on different platforms and security levels to protect the transmitted data from any possible attacks is one of the most important issues in today’s … …American Journal of Engineering and Applied Sciences, Vol. 4, Issue 4 · 12 Jan 2012 · 7,448 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleInvestigation of the Critical Clearing Time of Power System with Synchronous Machine Model Including SaliencyPrechanon KumkratugProblem statement: Most of synchronous generator applied in power system is the salient pole type. Most of previous researches use non-salient model to evaluate the critical clearing time. Thus the results of critical clearing time of power system may be error. Approach: Thus this paper investigate the critical clearing time of power system with synchronous machine. The mathematical model of … …American Journal of Applied Sciences, Vol. 9, Issue 2 · 21 Dec 2011 · 7,481 accessesView PDFCite
Research ArticleOpen accessEvery word in the titlePower Quality Analysis in 6 MW Wind Turbine Using Static Synchronous CompensatorR. Valarmathi, A. ChilambuchelvanProblem statement: An inherent problem with wind turbine power generation systems is the low power quality due to intermittent power generation in these systems. This not only affects the power generation but also the grid it is connected to. Approach: In this study a configuration consisting of a 6MW Wind Farm based on conventional Fixed Speed Induction Generator is analyzed. … …American Journal of Applied Sciences, Vol. 9, Issue 1 · 23 Nov 2011 · 7,232 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleDesign of Low- Power High-Speed Error Tolerant Shift and Add MultiplierK. N. Vijeyakumar, V. Sumathy, Sriram Komanduri, C. Chrisjin Gnana SujiProblem Statement: In this study, we had proposed a low power architecture for high speed multiplication. Approach: The modifications to the conventional shift and add multiplier includes introduction of modified error tolerant technique for addition and enabling of adder cell by current multiplication bit of the multiplier constant. The proposed architecture enables the removal of input multiplexer, switching of adder … …Journal of Computer Science, Vol. 7, Issue 12 · 18 Oct 2011 · 7,155 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleTrade Promotions and Suppliers' Market PowerSandra Mottner, Steven H. Smith, T. J. OlneyProblem statement: Trade promotions provided to retailers from suppliers are not well understood and have not been consistently reported by manufacturers. Research about the phenomenon has consequently been limited and neither the trade nor government agencies fully understand the phenomenon and its implications. One implication is that some trade promotions (or trade allowances as they are also known) can pose … …American Journal of Economics and Business Administration, Vol. 3, Issue 3 · 19 Sep 2011 · 7,088 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleSTATCOM Stabilizer based on Fuzzy Logic Control for Damping Power OscillationPrechanon KumkratugProblem statement: In power systems, there exists a continuous challenge to improve dynamic performance of power system. Approach: Static Synchronous Compensator (STATCOM) is a power electronic based device that has the capability of controlling the power flow through a line. This study applies the Static Synchronous Compensator (STATCOM) to control the power flow during dynamic period. To verify the effect … …American Journal of Applied Sciences, Vol. 8, Issue 10 · 8 Sep 2011 · 7,440 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleStatic Var Compensator based on Fuzzy Logic Control for Damping Power System OscillationPrechanon KumkratugProblem statement: The disturbance in power system is unavoidable situation. It causes in power system oscillation. Approach: This study applied the Static Var Compensator (SVC) to damp power system oscillation. The fuzzy logic control is applied to determine the control strategy of SVC. The simulation results are tested on a Single Machine Infinite bus. The proposed method is equipped in … …American Journal of Applied Sciences, Vol. 8, Issue 10 · 8 Sep 2011 · 7,265 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleDesign For Test Technique for Leakage Power Reduction in Nanoscale Static Random Access MemoryN. M. Sivamangai, GunavathiProblem statement: As technology scales down, the integration density of transistors increases and most of the power is dissipated as leakage. Leakage power reduction is achieved in Static Random Access Memory (SRAM) cells by increasing the source voltage (source biasing) of the SRAM array. Another promising issue in nanoscaled devices is the process parameter variations. Due to these variations, higher … …Journal of Computer Science, Vol. 7, Issue 8 · 15 Jul 2011 · 6,505 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleInter-Area Power Systems Stability Improvement by Static Synchronous Series CompensatorPrechanon KumkratugProblem statement: The inter-area power systems have special characteristic of the stability behavior. The improvement of inter-area power system is one of the important aspects in power system. Approach: This study applies the Static Synchronous Series Compensator (SSSC) to improve stability of inter-area systems. The SSSC is modeled and then is applied to be incorporated into the power system model … …American Journal of Applied Sciences, Vol. 8, Issue 7 · 24 Jun 2011 · 7,006 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleEvaluation of Critical Clearing Time of Power System Equipped With a Series FACT DevicesPrechanon KumkratugProblem statement: The critical clearing time provides very important role of the robustness in power system. The Static Synchronous Series Compensator (SSSC) has been accepted to be equipped in series with modern power system. This study presents the method to evaluate the Critical Clearing Time (CCT) of the system equipped with a SSSC. Approach: The parameter on SSSC is modeled … …Journal of Computer Science, Vol. 7, Issue 6 · 14 Jun 2011 · 6,777 accessesView PDFCite