Research ArticleOpen accessIn the abstractCost-Effective Energy Refurbishment of Health Care Facilities in Heating Dominated Climates of Italian Backcountry. The Case Study of the Hospital Veneziale of IserniaRosa Francesca De Masi, Fabrizio Ascione, Gennaro Sosto, Giuseppe Peter VanoliMaximizing energy efficiency within hospitals and healthcare facilities is a major challenge for sustainable development and energy saving objectives. In this study, the case study of the public hospital of Isernia (Italian backcountry city) is proposed, being typical of the hospital building stock developed in reinforced concrete all around Italy in the last 40 years. Starting from deep on-site investigations, … …American Journal of Engineering and Applied Sciences, Vol. 10, Issue 3 · 25 Sep 2017 · 8,354 accessesView PDFCite
Research ArticleOpen accessIn the abstractParameters Affecting the Performance of a Plate Heat Exchanger using the CFDKutay Aydın, Onur Vahip Güler, Ali KeçebaşA plate heat exchanger is a type of heat exchangers that provides more surface area for heat transfer between two fluids. Plate heat exchangers are widely used for heat transfer applications in the industry. In addition, they are now widely used in many applications such as food processing, chemical reaction processes, heating and cooling applications in sectors such as petroleum. … …Energy Research Journal, Vol. 8, Issue 2 · 15 Aug 2017 · 8,678 accessesView PDFCite
Research ArticleOpen accessIn the abstractOptimized Energy Efficient Virtual Machine Placement Algorithm and Techniques for Cloud Data CentersSanjay Patel, Ramji M. MakwanaCloud computing is an internet based computing technology that provide on demand computing for end users. Normally, data centers allocation for application on statically based. But today so many data centers have a problem how to reduce energy consumption? Due to increase use of cloud services and infrastructure by various cloud providers, uses of energy day by day increase that's … …Journal of Computer Science, Vol. 12, Issue 9 · 24 Nov 2016 · 7,359 accessesView PDFCite
Research ArticleOpen accessIn the abstractGas Atomization of Molten Metal: Part II. ApplicationsTaher M. Abu-Lebdeh, Genaro Pérez-de León, Sameer A. Hamoush et al.A numerical model was derived to obtain results for two alloys during the Gas Atomization (GA) method. The model equations and governing equations were implemented through the application of part I data. Aspects such as heat transfer, fluid mechanics, thermodynamics and law of motions were taken into account for the formulation of equations that take gas dynamics, droplet dynamics and … …American Journal of Engineering and Applied Sciences, Vol. 9, Issue 2 · 19 Apr 2016 · 8,365 accessesView PDFCite
Research ArticleOpen accessIn the abstractGas Atomization of Molten Metal: Part I. Numerical Modeling ConceptionGenaro Pérez-de León, Vincent E. Lamberti, Roland D. Seals et al.This numerical analysis study entails creating and assessing a model that is capable of simulating molten metal droplets and the production of metal powder during the Gas Atomization (GA) method. The essential goal of this research aims to gather more information on simulating the process of creating metal powder. The model structure and perspective was built through the application of … …American Journal of Engineering and Applied Sciences, Vol. 9, Issue 2 · 10 Apr 2016 · 9,053 accessesView PDFCite
Research ArticleOpen accessIn the abstractInfluence of Flow Direction on Vortex Flow Structure, Heat Transfer and Performance Improvement in Tube with V-Discreted BafflesWithada Jedsadaratanachai, Amnart BoonloiNowadays, the compact heat exchanger is used widely like a radiator, evaporator and condenser of air condition system, cooling device of electronic. Extensive studies have been done on the heat transfer characteristics and flow structure for the heat exchanger with longitudinal vortex generators by numerical method. Periodic laminar flow and heat transfer characteristics in a three-Dimensional (3D) isothermal circular tube … …American Journal of Applied Sciences, Vol. 11, Issue 11 · 7 Jan 2015 · 6,717 accessesView PDFCite
Research ArticleOpen accessIn the abstractTHE EFFECT OF VENTILATION AND ECONOMIZER ON ENERGY CONSUMPTIONS FOR AIR SOURCEHEAT PUMPS IN SCHOOLSNihal Al Raees, Nabil Nassif, Fouad Al RifaieThe study discusses the applications of CO2-based demand-controlled ventilation DCV strategy integrated with the economizer for air source heat pumps in schools, investigates their impact on the annual heating, cooling and total energy consumption, also determines the potential savings achieved in different USA locations. The study includes detailed energy analysis on an existing middle school through whole building simulation energy … …American Journal of Engineering and Applied Sciences, Vol. 7, Issue 1 · 18 Mar 2014 · 8,390 accessesView PDFCite
Research ArticleOpen accessIn the abstractINVESTIGATIONS ON THE PERFORMANCE OF VAPOUR COMPRESSION SYSTEM RETROFITTED WITH ZEOTROPIC REFRIGERANT R404AA. Lovelin Jerald, D. SenthilKumaranThe environmental impacts like global warming and ozone depletion has become a challenge to the refrigeration and air conditioning industry. Chloro Fluoro Carbons (CFCs) and Hydro Flouro Carbons (HCFCs) are referred to as an Ozone Depleting Substances (ODS) because once these gases are released into the environment and reach the stratosphere, depletes the ozone layer. This research paper aims to … …American Journal of Environmental Sciences, Vol. 10, Issue 1 · 11 Feb 2014 · 7,630 accessesView PDFCite
Research ArticleOpen accessIn the abstractAN EXPERIMENTAL STUDY ON HEAT TRANSPORT CAPABILITY OF A TWO PHASE THERMOSYPHON CHARGED WITH DIFFERENT WORKING FLUIDSM. Kannan, R. Senthil, R. Baskaran, B. DeepanrajIn the present investigation a two phase thermosyphon has been fabricated to investigate the effect of operating parameters on the heat transport capability. The system consists of evaporator section, adiabatic section and condenser section with thermocouples located on the wall of thermosyphon. Electric heater was fixed on the bottom of the evaporator section and water jacket for cooling the condenser … …American Journal of Applied Sciences, Vol. 11, Issue 4 · 1 Feb 2014 · 6,528 accessesView PDFCite