Sign inSubmit
ArticleMetrics
Research Article · Free to read · Published 11 February 2014

INVESTIGATIONS ON THE PERFORMANCE OF VAPOUR COMPRESSION SYSTEM RETROFITTED WITH ZEOTROPIC REFRIGERANT R404A

A. Lovelin Jerald1 & D. SenthilKumaran2

American Journal of Environmental Sciences, Volume 10, Issue 1, pp. 35–43 · doi.org/10.3844/ajessp.2014.35.43

7,626 accesses9,205 downloads6 citations (Crossref)Metrics
Cite Check for updates

Abstract

The environmental impacts like global warming and ozone depletion has become a challenge to the refrigeration and air conditioning industry. Chloro Fluoro Carbons (CFCs) and Hydro Flouro Carbons (HCFCs) are referred to as an Ozone Depleting Substances (ODS) because once these gases are released into the environment and reach the stratosphere, depletes the ozone layer. This research paper aims to study the performance characteristics of an R12 (CFC) vapour compression refrigeration system retrofitted with zeotrope blend of refrigerant R404a, used for cooling liquids with five different configuration of capillaries of diameters 0.033", 0.036", 0.044", 0.050" and 0.30" (2 Way). The refrigerant R404a is an alternate refrigerant to CFCs and HCFCs as they are ozone friendly and have less Global Warming Potential (GWP) than R12 and R134a. The parameters employed in analysis of the performance characteristics are the Evaporator load (Qe), Coefficient of Performance (COP), Work done by the compressor (Wc) and Refrigeration Effect (RE). A detailed experimentation was carried out to compare the performance and effectiveness of the system using five different capillaries. The result obtained from the observation will help to identify the optimum diameter of capillary which could be used in the system to give the best performance.

Licence and reuse

Free to read. This article carries the publisher’s copyright, as printed on it: © 2014 Science Publications. It is free to read; ask us before reusing it.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Jerald, A. L. & SenthilKumaran, D. (2014). INVESTIGATIONS ON THE PERFORMANCE OF VAPOUR COMPRESSION SYSTEM RETROFITTED WITH ZEOTROPIC REFRIGERANT R404A. American Journal of Environmental Sciences, 10(1), 35–43. https://doi.org/10.3844/ajessp.2014.35.43

Licence
© Science Publications
Issue
Volume 10, Issue 1
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
INVESTIGATIONS ON THE PERFORMANCE OF VAPOUR COMPRESSION SYSTEM RETROFITTED WITH ZEOTROPIC REFRIGERANT R404AAmerican Journal of Environmental Sciences · Volume 10, Issue 1 · pp. 35–43 · © Science PublicationsDownload