Sign inSubmit
Tips: “quotes” for a phrase · author:Lee · a DOI goes straight to its article

34 articles for “reactive power”

Set a search alert
Also matching:5 special issues
Research ArticleOpen accessIn the abstractEnergy Aware Multiple Constraints Quality of Service Routing Protocol with Dynamic Mobility Prediction for Mobile Ad hoc NetworksSenthilkumar Maruthamuthu, Somasundaram SankaralingamProblem statement: This study presents a source based reactive protocol called "Energy Aware Multiple Constraints QoS Routing Protocol with Dynamic Mobility Prediction (EMQRPDM)" for MANET. It is an enhanced version of our previous protocol called "Power aware multiple QoS constraints routing protocol with mobility prediction (PMQRPMP)". It addresses the issues such as routing, mobility and power management in MANET. Approach: … …Journal of Computer Science, Vol. 7, Issue 6 · 14 Jun 2011 · 6,477 accessesView PDFCite
Research ArticleOpen accessIn the abstractFuzzy Logic Controller for Static Synchronous Series Compensator with Energy Storage System for Transient Stability AnalysisSona Padma, M. RajaramProblem statement: FACTS devices play a major role in the efficient operation of the complex power system. FACTS devices such as STATCOM, SSSC and IPFC are in increasing usage. With energy storage systems they have a good control over the real as well as reactive power compensation and transient stability improvement. The design of controller for the SSSC with SMES … …Journal of Computer Science, Vol. 7, Issue 6 · 14 Jun 2011 · 6,694 accessesView PDFCite
Research ArticleOpen accessIn the abstractAn Effective Location-Based Power Conservation Scheme for Mobile Ad Hoc NetworksKhalid Kaabneh, Azmi Halasa, Hussein Al-BahadiliProblem statement: One of the major issues in current reactive routing protocols for Mobile Ad Hoc Networks (MANETs) is the high bandwidth and power consumptions during the routing process. In this study, we proposed and evaluated the performance of an efficient Location-Based Power Conservation (LBPC) scheme for MANETs. Approach: In this scheme, the transmitting node utilized the location-information of the … …American Journal of Applied Sciences, Vol. 6, Issue 9 · 30 Sep 2009 · 6,836 accessesView PDFCite
Research ArticleOpen accessIn the abstractElectric Power System Under-Voltage Load Shedding Protection Can Become a TrapLuiz Augusto Pereira Fernandes, Alexandre Rocco, Heraldo Silveira Barbuy, Geraldo Caixeta GuimarãesProblem statement: Under-Voltage Load Shedding (UVLS) protection of Electric Power Systems (EPS) is frequently used against Voltage Collapse (VC), however when there is automatic bus voltage regulation with excessive capacitive compensation, the UVLS scheme may not trip. In this case, load shedding must be based in a Voltage Collapse Proximity Indicator (VCPI). Many UVLS procedures may not be appropriate today. … …American Journal of Applied Sciences, Vol. 6, Issue 8 · 31 Aug 2009 · 7,203 accessesView PDFCite
Research ArticleOpen accessIn the abstractOptimal Location of Static Var Compensator Device for Damping OscillationsM. W. Mustafa, N. MagajiProblem statement: Static Var Compensators (SVC) devices are used to improve voltage and reactive power conditions in AC systems. An additional task of SVC is to increase transmission capacity as result of power oscillation damping. The effectiveness of this controller depends on its optimal location and proper signal selection in the power system network. A residue factor had been proposed … …American Journal of Engineering and Applied Sciences, Vol. 2, Issue 2 · 30 Jun 2009 · 8,371 accessesView PDFCite
Research ArticleOpen accessIn the abstractPerformance Comparison of Three-Phase Shunt Active Power Filter AlgorithmsMoleykutty George, Kartik Prasad BasuThe usage of parallel converters is ever increasing. However, the voltage and current harmonics, zero-sequence and negative- sequence components of voltage and current and reactive power present in parallel converters give an alarming signal to power system and power electronic engineers. This research discusses performance of three-phase shunt active power filter (APF) system using three different control techniques namely synchronous … …American Journal of Applied Sciences, Vol. 5, Issue 11 · 30 Nov 2008 · 6,810 accessesView PDFCite
Research ArticleOpen accessIn the abstractModeling and Control of Three-Phase Shunt Active Power FilterMoleykutty George, Kartik Prasad BasuIn this research the performance of a three-phase shunt active power filter (APF) using Model Reference Controller (MRC) has been compared with that using instantaneous active and reactive (p-q) theory. The novelty of this research lies in the application of MRC to generate the amplitude of the reference supply current required by the APF circuit and the successful implementation of … …American Journal of Applied Sciences, Vol. 5, Issue 8 · 31 Aug 2008 · 7,501 accessesView PDFCite
Research ArticleOpen accessIn the abstractA Multi-Objective HPSO Algorithm Approach for Optimally Location of UPFC in Deregulated Power SystemsSeyed Abbas Taher, Seyed Mohammad Hadi TabeiThis paper presents the application of hybrid particle swarm optimization technique to find optimal location of unified power flow controller to achieve optimal power flow. Objective function in the OPF, that is to be minimized, are the overall cost functions, which include the total active and reactive production cost function of the generators and installation cost of UPFCs. The OPF … …American Journal of Applied Sciences, Vol. 5, Issue 7 · 31 Jul 2008 · 6,975 accessesView PDFCite
Research ArticleOpen accessIn the abstractTransmission Congestion Management by Determining Optimal Location of FACTS Devices in Deregulated Power SystemsSeyed Abbas Taher, Hadi BesharatIn a deregulated electricity market, it may always not be possible to dispatch all of the contracted power transactions due to congestion of the transmission corridors. The ongoing power system restructuring requires an opening of unused potentials of transmission system due to environmental, right-of-way and cost problems which are major hurdles for power transmission network expansion. Flexible ac transmission systems … …American Journal of Applied Sciences, Vol. 5, Issue 3 · 31 Mar 2008 · 8,505 accessesView PDFCite
Research ArticleOpen accessIn the abstractFast Power Loss Computation and Shunt Capacitor Insertion Using Fuzzy Logic TechniqueWagah F. Mohammad, Nabil Tawalbeh, Kasim M. Al-AubidyFast power loss computation was implemented using supervisory control and data acquisition system (SCADA) with personal computer. Logic Control Array (LCA) and EPROM circuits were used to implement SCADA system to facilitate the required measurements to obtain the daily load profile for residential and commercial customers. LCA, EPROM and PC were used to simplify the electronic circuits, reduce the cost … …American Journal of Applied Sciences, Vol. 4, Issue 1 · 30 Apr 2007 · 7,391 accessesView PDFCite