Sign inSubmit
ArticleMetrics
Research Article · Open access · Published 24 October 2016

Comparison of Improved Semi-Automated Segmentation Technique with Manual Segmentation: Data from the Osteoarthritis Initiative

Hong Seng Gan1 & Khairil Amir Sayuti2

American Journal of Applied Sciences, Volume 13, Issue 11, pp. 1068–1075 · doi.org/10.3844/ajassp.2016.1068.1075

7,363 accesses3,983 downloads6 citations (Crossref)Metrics
Cite Check for updates

Abstract

Manual segmentation is the standard procedure in osteoarthritis study. However, this method is infamous for being excessive, time consuming and exhaustive. In this study, we overcame the problem of excessive expert interaction reported in manual segmentation by developing a semi-automated random walks technique with computer-aided labelling system. To minimize expert interaction, non-cartilage seeds were generated by using computer. Then, random walks algorithm would segment knee cartilage based on cartilage seeds and non-cartilage seeds. Finally, segmentation results were revised and refined accordingly. A total of 15 normal images and 10 osteoarthritic images were used in this study. In term of efficiency, we have reduced the processing time to segment normal cartilage by 47.5% (93±21s; P = 0.0000019) for observer 1 and 44% (61±8s; P = 3.52×10-5) for observer 2. We also reduced the processing time to segment diseased cartilage by 48.1% (56±16s; P = 0.00014) for observer 1 and 30.3% (62±14s; P = 0.0070) for observer 2. Besides, the proposed technique have produced good reproducibility in both normal (0.83±0.028 for observer 1 and 0.80±0.040 for observer 2) and diseased (0.80±0.060 for observer 1 and 0.82±0.043 for observer 2) cartilage segmentations. In conclusion, the combination of computer generated seeds and user-friendly random walks method have reduced the amount of expert interaction to necessary level without compromising the accuracy of results.

Licence and reuse

Open access. This article is licensed under a Creative Commons Attribution 3.0 Licence (CC BY 3.0), as printed on the article, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original authors and the source. No permission is needed.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Gan, H. S. & Sayuti, K. A. (2016). Comparison of Improved Semi-Automated Segmentation Technique with Manual Segmentation: Data from the Osteoarthritis Initiative. American Journal of Applied Sciences, 13(11), 1068–1075. https://doi.org/10.3844/ajassp.2016.1068.1075

Licence
CC BY 3.0
Issue
Volume 13, Issue 11
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
Comparison of Improved Semi-Automated Segmentation Technique with Manual Segmentation: Data from the Osteoarthritis InitiativeAmerican Journal of Applied Sciences · Volume 13, Issue 11 · pp. 1068–1075 · CC BY 3.0Download