Sign inSubmit
ArticleMetrics
Research Article · Free to read · Published 16 May 2012

Thermal Comfort Assessment-A Study Toward Workers’ Satisfaction in a Low Energy Office Building

Mohd Nafiz Shaharon1 & Juliana Jalaludin1

American Journal of Applied Sciences, Volume 9, Issue 7, pp. 1037–1045 · doi.org/10.3844/ajassp.2012.1037.1045

8,797 accesses5,529 downloads26 citations (Crossref)Metrics
Cite Check for updates

Abstract

Problem statement: The government of Malaysia has raised their concerns towards the issue of workers comfort and workspace quality in a Low Energy Office (LEO) building. New energy efficient building concepts and technologies require a revision of comfort standards, to create a suitable thermal condition in avoiding occupant dissatisfaction, adverse effect on their productivity and overall building performance. Approach: Assessment was conducted using Babuc-A (Portable air quality monitor) and sets of questionnaire adapted from ASHRAE-2004 were 99 respondents selected using a stratified random sampling. Results: This study shows that the thermal comfort zone temperature was identified to be within the range of 21.6-23.6°C and relative humidity of 42-54%. Conclusion: The results suggested that the thermal condition was in the acceptable range of ISO7730 and a lower room temperature was preferred by Malaysian in an office environment compared with the temperature criteria cited in ASHRAE-55. To create an optimum comfortable workplace, temperature between 20-26°C and relative humidity between 40-60% must be maintained. Adequate ventilation must be provided at the minimum rate of 10 l/s of fresh air per person for general office space or every 10 m2 of floor space.

Licence and reuse

Free to read. This article carries the publisher’s copyright, as printed on it: © 2012 Science Publications. It is free to read; ask us before reusing it.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Shaharon, M. N. & Jalaludin, J. (2012). Thermal Comfort Assessment-A Study Toward Workers’ Satisfaction in a Low Energy Office Building. American Journal of Applied Sciences, 9(7), 1037–1045. https://doi.org/10.3844/ajassp.2012.1037.1045

Licence
© Science Publications
Issue
Volume 9, Issue 7
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
Thermal Comfort Assessment-A Study Toward Workers’ Satisfaction in a Low Energy Office BuildingAmerican Journal of Applied Sciences · Volume 9, Issue 7 · pp. 1037–1045 · © Science PublicationsDownload