Sign inSubmit
ArticleArticle metrics
Research Article · Free to read · Published 31 May 2009

Effective Ventilation Parameters and Thermal Comfort Study of Air-conditioned Offices

Roonak Daghigh & Kamaruzzaman Sopian

American Journal of Applied Sciences, Volume 6, Issue 5, pp. 943–951 · doi.org/10.3844/ajassp.2009.943.951

7,586 accesses5,308 downloads13 citations (Crossref)Journal metrics
Cite Check for updates

Abstract

The study presents objective and subjective studies of thermal comfort levels and ventilation characteristics of two air-conditioned postgraduate study offices. The observations were performed at the offices of Department of Electrical and Electronic Engineering, in University Putra Malaysia. Thermal comfort variables were measured while the students answered a survey on their sensation of the indoor climate. Concurrently, tracer gas analysis, based on concentration decay method, is employed to determine air exchange rate, age of air and air exchange effectiveness. During the air conditioner is working, the study offices had not conditions within the comfort zone, of ASHRAE standard 55 causing occupants to report cold thermal sensations and the objective data analysis showed that the offices were uncomfortable. The thermal neutralities were significantly higher that proposed by ASHRAE Standard 55:1992. The monitored air exchange rates are indicated that the provisions of outside air for ventilation based on design occupancy are adequate for these two study offices. In addition, questionnaires were completed by the students in order to provide a subjective assessment of thermal comfort and indoor air quality. Finally, the outcomes of over 30 surveys for each office responses to the thermal comfort questions are presented and discussed.

Licence and reuse

Free to read. This article carries the publisher’s copyright, as printed on it: © 2009 Science Publications. It is free to read; ask us before reusing it.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Daghigh, R. & Sopian, K. (2009). Effective Ventilation Parameters and Thermal Comfort Study of Air-conditioned Offices . American Journal of Applied Sciences, 6(5), 943–951. https://doi.org/10.3844/ajassp.2009.943.951

Licence
© Science Publications
Issue
Volume 6, Issue 5
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
Effective Ventilation Parameters and Thermal Comfort Study of Air-conditioned OfficesAmerican Journal of Applied Sciences · Volume 6, Issue 5 · pp. 943–951 · © Science PublicationsDownload