Sign inSubmit
ArticleMetrics
Research Article · Free to read · Published 30 April 2008

Effect of Stent Geometry on Phase Shift between Pressure and Flow Waveforms in Stented Human Coronary Artery

Vahab Dehlaghi, Siamak Najarian & Mohammad Tafazzoli Shadpour

American Journal of Applied Sciences, Volume 5, Issue 4, pp. 340–346 · doi.org/10.3844/ajassp.2008.340.346

7,252 accesses4,740 downloads7 citations (Crossref)Metrics
Cite Check for updates

Abstract

Shear stress is known to play a central role in restenosis formation and is sensitive to stent geometry. Alterations of the phase shift between pressure and flow waveform created by a different stents were studied to compare the hemodynamic effects of stent design properties on restenosis in stented human coronary artery. Blood pressure waveforms were computed in three different sites, pre-stent, middle of stented arterial segment, and post-stent regions using computational fluid dynamics. Blood flow was assumed as pulsatile, incompressible, and Newtonian flow. Rigid boundary conditions were assumed for all models. The governing Navier-Stokes equations were solved using commercial software package (Fluent V6.0.12). Stents were assumed with real structure and modeled using the commercial software package (Gambit, V2.0). The alterations of the phase shift between pressure and flow waveform created by a different stents were investigated in three major regions using commercial software package (Matlab, V7.0). It is concluded that stent geometry changes the phase shift between pressure and flow waveforms in stented human coronary artery, and wall shear stress between stent struts was sensitive to these variations. The results show that variation in the phase shift is sensitive to stent geometry.

Licence and reuse

Free to read. This article carries the publisher’s copyright, as printed on it: © 2008 Science Publications. It is free to read; ask us before reusing it.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Dehlaghi, V., Najarian, S. & Shadpour, M. T. (2008). Effect of Stent Geometry on Phase Shift between Pressure and Flow Waveforms in Stented Human Coronary Artery. American Journal of Applied Sciences, 5(4), 340–346. https://doi.org/10.3844/ajassp.2008.340.346

Licence
© Science Publications
Issue
Volume 5, Issue 4
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
Effect of Stent Geometry on Phase Shift between Pressure and Flow Waveforms in Stented Human Coronary ArteryAmerican Journal of Applied Sciences · Volume 5, Issue 4 · pp. 340–346 · © Science PublicationsDownload