Numerical Analysis of Pulsatile Blood Flow in a Stented Human Coronary Artery with a Flow Divider

Vahab Dehlaghi, Mohammad Tafazoli Shadpoor & Siamak Najarian

American Journal of Applied Sciences, Volume 4, Issue 6, pp. 397–404 · doi.org/10.3844/ajassp.2007.397.404

6,521 accesses5,252 downloads2 citations (Crossref)Metrics
Cite Check for updates

Abstract

Shear stress is known to play a central role in restenosis formation and is sensitive to stent geometry. Local flow alterations created by a different stents without and with flow divider were studied to compare the hemodynamic effects of Stent design properties on restenosis in stented human coronary artery. Blood pressure and shear stress values were computed in three different sites, including stented arterial segment, pre-stent and post-stent regions using computational fluid dynamics. Blood flow was assumed as pulsatile, incompressible and Newtonian flow. Rigid boundary conditions were assumed for all models. The governing Navier-Stokes equations were solved using commercial software package (Fluent V6.0.12). Stents are assumed with real structure and modeled using the commercial software package (Gambit, V2.0). The arterial wall shear stress distribution was investigated in three major regions and critical sites were located. It is concluded that the wall shear stress between stent struts was sensitive to strut spacing, profile of strut, number of struts and curvature. Our 3D computational fluid dynamics modeling demonstrate that with increasing the angle between two sides of the stent strut the percentage of intrastrut area that exposed to critical value of WSS decreases. By application of a flow divider, the wall shear stress in stented segment increases markedly and so is the pressure gradient in stented segment. Flow divider influences the blood flow pattern in proximal of stented segment. In this section, the WSS increases with application of the flow divider. The results for different diameters of flow divider show that optimum diameter for flow divider is D/3.

Licence and reuse

Free to read. This article carries the publisher’s copyright, as printed on it: © 2007 Science Publications. It is free to read; ask us before reusing it.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Dehlaghi, V., Shadpoor, M. T. & Najarian, S. (2007). Numerical Analysis of Pulsatile Blood Flow in a Stented Human Coronary Artery with a Flow Divider . American Journal of Applied Sciences, 4(6), 397–404. https://doi.org/10.3844/ajassp.2007.397.404

Licence
© Science Publications
Issue
Volume 4, Issue 6
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
Numerical Analysis of Pulsatile Blood Flow in a Stented Human Coronary Artery with a Flow DividerAmerican Journal of Applied Sciences · Volume 4, Issue 6 · pp. 397–404 · © Science PublicationsDownload