Sign inSubmit
Tips: “quotes” for a phrase · author:Lee · a DOI goes straight to its article

78 articles for “fracture”

Set a search alert
Also matching:2 special issues
Research ArticleOpen accessEvery word in the titleAnalytical Fractured Reservoir Characterization by using Geological and Petrophysical LogsZohreh Movahed, Farzaneh AghajariDue to structural complexities in some wells, higher than the expected thickness of the Asmari formation is found. Fracture intensity and deep-rooted fractures broadly increase the risk of unpredictable water production. The well-test analysis is not sufficient in describing fracture properties. Unfortunately, the core condition is poor in the fractured zones and cannot be used to provide reliable information. So, … …Current Research in Geoscience, Vol. 12, Issue 1 · 3 Dec 2022 · 9,927 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleClassifications of Skull Fractures using CT Scan Images via CNN with Lazy Learning ApproachMd Moniruzzaman Emon, Tareque Rahman Ornob, Moqsadur RahmanClassification of skull fracture is a challenging task for both radiologists and researchers. Skull fractures result in broken pieces of bone, which can cut into the brain and cause bleeding and other injury types. So it is vital to detect and classify the fracture very early. In real world, often fractures occur at multiple sites. This makes it harder to … …Journal of Computer Science, Vol. 18, Issue 3 · 15 Mar 2022 · 9,005 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleExploratory Study on the Fracture Resistance of Cast GlassTelesilla Bristogianni, Faidra Oikonomopoulou, Fred Veer, Rob NijsseThe emerging interest in the architectural applications of cast glass components reveals a knowledge gap on the mechanical properties of cast glass. Apart from its chemical composition, cast glass is characterized by its manufacturing history and thermal profile, often inheriting a set of defects that define its properties. The role that inhomogeneities in the bulk of voluminous glass components have … …International Journal of Structural Glass and Advanced Materials Research, Vol. 5, Issue 1 · 4 Jun 2021 · 7,356 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleThe Effect of Pulsed Electromagnetic Field Exposure on Fracture Healing Through the Wnt Signal PathwayUmiatin U, Ismail Hadisoebroto Dilogo, Puji Sari, Sastra Kusuma WijayaPulsed Electromagnetic Fields (PEMF) is reported to encourage the healing of nonunion fractures. However, the mechanism by which this occurs is still not known. Wnt signaling pathways are believed to be important signaling pathways in bone formation. This study will evaluate the healing of delayed union femur fracture, given PEMF exposure. 48 Spraque Dawley rats were fracturized at the left … …OnLine Journal of Biological Sciences, Vol. 20, Issue 4 · 14 Dec 2020 · 6,653 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleRecent Results on the Brittle Fracture of Terfenol-D Specimens under Magnetic FieldMarco Colussi, Kotaro Mori, Fumio NaritaThe following investigation has the purpose of describing, both experimentally and numerically, the fracture behavior of a giant magnetostrictive alloy commercially known as Terfenol-D. Single-edge precracked specimens have been analyzed via three-point bending tests, measuring fracture loads in the presence and absence of a magnetic field at various loading rates. The Strain Energy Density (SED), averaged in a finite control … …American Journal of Engineering and Applied Sciences, Vol. 9, Issue 4 · 28 Dec 2016 · 7,772 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleRobustness of XFEM Method for the Simulation of Cracks Propagation in Fracture Mechanics ProblemsAniello Riccio, Umberto Caruso, Antonio Raimondo, Andrea SellittoIn the present paper a numerical sensitivity analysis is presented with the aim to assess the effectiveness of the X-FEM method for fracture mechanics applications. Different test cases have been adopted for the numerical analyses to point out the X-FEM method behavior in 2-D and 3-D elastic and elasto-plastic conditions. Comparisons with a standard ductile damage model have been carried … …American Journal of Engineering and Applied Sciences, Vol. 9, Issue 3 · 15 Aug 2016 · 8,287 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleFracture Initiation at the Zirconia/Veneer Interface-A Finite Element SimulationMirsayar M. M., A. T. SamaeiZirconia/veneer bilayered components are extensively used in dental restoration technology to improve resistance of tooth's surface from decay. The direction of the fracture propagation at the interface of zirconia and veneer is investigated in this study. Finite element analysis is performed on a bi-material four point bend specimen in different geometries and the fracture initiation angle is obtained using Maximum … …American Journal of Engineering and Applied Sciences, Vol. 8, Issue 3 · 8 Jun 2015 · 7,567 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleThe Outcome of Conservative Treatment of Closed Fracture Shaft Humerus in Adult PatientsM. Taha MuzahimProblem statement: Fractures of the humeral shaft are commonly encountered by the orthopaedic surgeons; accounting for approximately 3% of all fractures. There is a wide array of good options for their treatment and controversy over the best methods for many situations. Appropriate nonoperative and operative treatment of patients with humeral shaft fractures, however, requires an understanding of humeral anatomy, the … …Current Research in Medicine, Vol. 2, Issue 1 · 9 May 2011 · 8,016 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleGray-Level Co-occurrence Matrix Bone Fracture DetectionHum Yan Chai, Lai Khin Wee, Tan Tian Swee et al.Problem statement: Currently doctors in orthopedic wards inspect the bone x-ray images according to their experience and knowledge in bone fracture analysis. Manual examination of x-rays has multitude drawbacks. The process is time-consuming and subjective. Approach: Since detection of fractures is an important orthopedics and radiologic problem and therefore a Computer Aided Detection(CAD) system should be developed to improve the … …American Journal of Applied Sciences, Vol. 8, Issue 1 · 31 Jan 2011 · 8,968 accessesView PDFCite
Research ArticleOpen accessEvery word in the titleFracture and springback on Double Bulge Tube Hydro-FormingF. Djavanroodi, M. GheisaryThis research aims to establish a basic understanding of Double Bulge Tube Hydro-Form processing of stainless steel deep drawn cups. The method is briefly reviewed by carrying out experimental tests and Finite element analysis. By measuring bulge height in both formed curves by Coordinate measuring machine (CMM) and thickness variation specimen by Ulterasonic thickness measurment device (UTM), it has been … …American Journal of Applied Sciences, Vol. 5, Issue 8 · 31 Aug 2008 · 6,889 accessesView PDFCite