Sign inSubmit
Tips: “quotes” for a phrase · author:Lee · a DOI goes straight to its article

76 results for “State Variable”

Set a search alert
Research ArticleOpen accessIn the abstractMethodical Tuning of Proportional Plus Integral Controllers for Cascade Control of Separately Excited DC MotorsIbrahim Al-AbbasThe cascade control of DC motors by PI controllers was extensively used in industry. Approximation rules based on plotting the output of the system or on computer simulation were used to determine the parameters of these controllers. This study was done to develop mathematical expressions to calculate the parameters of these controllers. Output time functions of the system and there … …American Journal of Applied Sciences, Vol. 9, Issue 11 · 12 Sep 2012 · 7,008 accessesView PDFCite
Research ArticleOpen accessIn the abstractDesign of a Fuzzy Logic Sliding mode Model Following Controller for a Brushless DC Servomotor DriversPhongsak PhakamachProblem statement: A brushless DC servomotor position control system using a fuzzy logic sliding mode model following controller or FLSMFC is presented. Approach: The FLSMFC structure consists of an integrator and variable structure system. Results: The integrator ensures the elimination of steady state error due to step and ramp command inputs, while the fuzzy control would maintain the insensitivity to … …Energy Research Journal, Vol. 2, Issue 1 · 26 Jan 2012 · 7,196 accessesView PDFCite
Research ArticleOpen accessIn the abstractInter-Area Power Systems Stability Improvement by Static Synchronous Series CompensatorPrechanon KumkratugProblem statement: The inter-area power systems have special characteristic of the stability behavior. The improvement of inter-area power system is one of the important aspects in power system. Approach: This study applies the Static Synchronous Series Compensator (SSSC) to improve stability of inter-area systems. The SSSC is modeled and then is applied to be incorporated into the power system model … …American Journal of Applied Sciences, Vol. 8, Issue 7 · 24 Jun 2011 · 7,006 accessesView PDFCite
Research ArticleOpen accessIn the abstractPhysical Composition, Nutrients and Contaminants of Typical Waste Dumping SitesH. Meuser, K. S. Grewal, R. Anlauf et al.Problem statement: The composition of wastes is quite variable depending upon the generating source and mode of collection. Most of the material from the domestic activities will be organic in nature and contains essential plant nutrients, whereas the dumping material of commercial and industrial wastes usually contains appreciable amounts of heavy and potentially toxic metals and organic pollutants. Approach: Objective … …American Journal of Environmental Sciences, Vol. 7, Issue 1 · 28 Feb 2011 · 7,753 accessesView PDFCite
Research ArticleOpen accessIn the abstractTransient in-Cylinder Gas Flow Characteristics of Single Cylinder Port Injection Hydrogen Fueled EngineM. M. Rahman, Khalaf I. Hamada, M. M. Noor et al.Problem statement: The variation of the in-cylinder gas flow characteristics for single cylinder port injection hydrogen fueled internal combustion engine was investigated through transient state simulation. Approach: One dimensional gas dynamics was described the flow and heat transfer in the components of the engine model. Special attention is paid to selection and correction of heat transfer correlation which describe of … …American Journal of Applied Sciences, Vol. 7, Issue 10 · 31 Oct 2010 · 8,647 accessesView PDFCite
Research ArticleOpen accessIn the abstractNetwork Data Envelopment Analysis Model for Estimating Efficiency and Productivity in UniversitiesMohammad Mahallati Rayeni, Faranak Hosseinzadeh SaljooghiProblem statement: The aim of this study was to compute disaggregate performance measures of universities. The traditional models for Data Envelopment Analysis (DEA) type performance measurement are based on thinking about production as a "black box". Inputs are transformed in this box into outputs. One of the drawbacks of these models is the neglect of linking activities. Approach: Network DEA … …Journal of Computer Science, Vol. 6, Issue 11 · 23 Oct 2010 · 7,880 accessesView PDFCite
Research ArticleOpen accessIn the abstractEvolution of a Graduate Environmental Science ProgramWill Focht, Talya HendersonProblem statement: Environmental science programs vary widely in their curricula and pedagogical approaches. In part, this is due to the lack of a unified agreement on field identity. However, program differences are also the product of variable program histories. Approach: This essay described the founding and subsequent history of the Environmental Science Graduate Program at Oklahoma State University, its oldest … …American Journal of Environmental Sciences, Vol. 5, Issue 2 · 30 Apr 2009 · 7,010 accessesView PDFCite
Research ArticleOpen accessIn the abstractReduced Order Models of a Current Source Inverter Induction Motor DriveIbrahim K. Al-AbbasProblem Statement: The current source inverter induction motor (CSI-IM) drive was widely used in various industries. The main disadvantage of this drive was nonlinearity and complexity. This work was done to develop a simple drive systems models. Approach: The MATLAB/SIMULINK software was used for system modeling. Three reduced models were developed by choosing specific frame, neglecting stator transients and ignoring … …American Journal of Engineering and Applied Sciences, Vol. 2, Issue 1 · 31 Mar 2009 · 7,865 accessesView PDFCite
Research ArticleOpen accessIn the abstractEffects of Spot Diameter and Sheets Thickness on Fatigue Life of Spot Welded Structure based on FEA ApproachM. M. Rahman, A. B. Rosli, M. M. Noor et al.This study presents the effect of the spot weld and sheets thickness on the fatigue life of the of the spot-weld joints to predict the lifetime and location of the weakest spot-welds due to the variable amplitude loading conditions. A simple model was used to illustrate the technique of spot-weld fatigue analysis. Finite element model and analysis were carried out … …American Journal of Applied Sciences, Vol. 6, Issue 1 · 31 Jan 2009 · 7,864 accessesView PDFCite
Research ArticleOpen accessIn the abstractReliability Parameters of a Power Generating System with Shared LoadRitu Gupta, S.K. Mittal, C.M. BatraThis study presents a model, based on power generating system with shared load. The whole generating system consists of three subsystems viz: subsystem A , subsystem B and subsystem C. The subsystem A consists of one generating unit and one inbuilt transformer. The subsystem B also contains the same units and is connected in parallel to subsystem A. The output … …Journal of Mathematics and Statistics, Vol. 3, Issue 4 · 31 Dec 2007 · 6,697 accessesView PDFCite