Sign inSubmit
Tips: “quotes” for a phrase · author:Lee · a DOI goes straight to its article

506 results for “Power system”

Set a search alert
Research ArticleOpen accessPhrase in the titleMitigation Voltage Sag in Power System by Static Synchronous CompensatorPrechanon KumkratugProblem statement: The disturbance in power system is unavoidable situation. It cause in voltage sag in power system. Approach: This study applied the STATCOM to mitigate voltage of the system. The mathematical model of power system equipped with a STATCOM is systematically derived. The presented mathematical model is shown how it effects on voltage sag improvement. The simulation results are … …American Journal of Applied Sciences, Vol. 7, Issue 12 · 31 Dec 2010 · 7,681 accessesView PDFCite
Research ArticleOpen accessPhrase in the titleApplication of Interline Power Flow Controller to Increase Transient Stability of Power SystemPrechanon KumkratugProblem statement: The Interline Power Flow Controller (IPFC) is a novel device which can increase transient stability of power system. To verify the capability of the effect of IPFC on stability improvement of power system, the suitable mathematical model and control strategy of IPFC are needed to be presented. Approach: This study presented the mathematical model and control strategy of … …Journal of Computer Science, Vol. 6, Issue 12 · 22 Nov 2010 · 7,642 accessesView PDFCite
Research ArticleOpen accessPhrase in the titlePower System Stability Enhancement Using Unified Power Flow ControllerPrechanon KumkratugProblem statement: The enhancement of transient stability of the power system is one of the most challenging research areas in power engineer. Approach: This study presents the method to enhance transient stability of power system by Unified Power Flow Controller (UPFC). The mathematical model of power system equipped with a UPFC is systematically derived. The parameters of UPFC are modeled … …American Journal of Applied Sciences, Vol. 7, Issue 11 · 8 Nov 2010 · 7,675 accessesView PDFCite
Research ArticleOpen accessPhrase in the titleImprovement of Transient Stability of Power System by Thyristor Controlled Phase Shifter TransformerPrechanon KumkratugProblem statement: The improvement of transient stability of the power system was one of the most challenging research areas in power engineer. Approach: This study presents the method to improve transient stability of power system by Thyristor Controlled Phase Shifter Transformer (TCPST). The mathematical model of power system equipped with a TCPST was systematically derived. The parameters of TCPST are … …American Journal of Applied Sciences, Vol. 7, Issue 11 · 8 Nov 2010 · 7,724 accessesView PDFCite
Research ArticleOpen accessPhrase in the titleFast Decoupled Power Flow for Power System with High Voltage Direct Current Transmission Line SystemPrechanon KumkratugProblem statement: High voltage direct current transmission line system has been widely applied for control power flow in power system. The power flow analysis was the one of powerful tools by which the power system equipped was analyzed both for planning and operation strategies. Approach: This study presented the method to analyze power flow of power system consisted of HVDC … …American Journal of Applied Sciences, Vol. 7, Issue 8 · 31 Aug 2010 · 7,010 accessesView PDFCite
Research ArticleOpen accessPhrase in the titleElectric Power System Under-Voltage Load Shedding Protection Can Become a TrapLuiz Augusto Pereira Fernandes, Alexandre Rocco, Heraldo Silveira Barbuy, Geraldo Caixeta GuimarãesProblem statement: Under-Voltage Load Shedding (UVLS) protection of Electric Power Systems (EPS) is frequently used against Voltage Collapse (VC), however when there is automatic bus voltage regulation with excessive capacitive compensation, the UVLS scheme may not trip. In this case, load shedding must be based in a Voltage Collapse Proximity Indicator (VCPI). Many UVLS procedures may not be appropriate today. … …American Journal of Applied Sciences, Vol. 6, Issue 8 · 31 Aug 2009 · 7,203 accessesView PDFCite
Research ArticleOpen accessPhrase in the titleDesign of New Load Shedding Special Protection Schemes for a Double Area Power SystemH. Seyedi, M. Sanaye-PasandIn this paper several Under Frequency Load Shedding (UFLS) schemes are designed as special protection schemes to preserve the integrity of islands, formed following the outage of tie lines connecting two areas in a double area power system. For the purpose of analysis, the Iranian interconnected grid is simulated in a suitable power system analysis software. The grid is connected … …American Journal of Applied Sciences, Vol. 6, Issue 2 · 28 Feb 2009 · 7,572 accessesView PDFCite
Research ArticleOpen accessPhrase in the titleOptimal Decentralized Load Frequency Control Using HPSO Algorithms in Deregulated Power SystemsSeyed Abbas Taher, Reza Hematti, Ali Abdolalipour, Seyed Hadi TabeiLoad Frequency Control (LFC) is one the most important issues in electrical power system design/operation and is becoming much more significant recently with increasing size, changing structure and complexity in interconnected power systems. In practice LFC systems use simple Proportional-Integral (PI) or Integral (I) controllers. However, since the PI or I control parameters are usually tuned based on classical or … …American Journal of Applied Sciences, Vol. 5, Issue 9 · 30 Sep 2008 · 7,389 accessesView PDFCite
Research ArticleOpen accessPhrase in the titleDesign of Robust UPFC Controller Using H∞ Control Theory in Electric Power SystemSeyed Abbas Taher, Shahabeddin Akbari, Ali Abdolalipour, Reza HemattiAn industrial plant, such a power system, always contains parametric uncertainties. In the design of a controller the uncertainties have to be considered. Otherwise, if the real plant differs from the assumed plant model, a controller, designed based on classical controller design approaches, may not ensure the stability of the overall system. In this paper design of robust control for … …American Journal of Applied Sciences, Vol. 5, Issue 8 · 31 Aug 2008 · 7,090 accessesView PDFCite
Research ArticleOpen accessPhrase in the titleA Multi-Objective HPSO Algorithm Approach for Optimally Location of UPFC in Deregulated Power SystemsSeyed Abbas Taher, Seyed Mohammad Hadi TabeiThis paper presents the application of hybrid particle swarm optimization technique to find optimal location of unified power flow controller to achieve optimal power flow. Objective function in the OPF, that is to be minimized, are the overall cost functions, which include the total active and reactive production cost function of the generators and installation cost of UPFCs. The OPF … …American Journal of Applied Sciences, Vol. 5, Issue 7 · 31 Jul 2008 · 6,975 accessesView PDFCite