Sign inSubmit
Tips: “quotes” for a phrase · author:Lee · a DOI goes straight to its article

114 articles for “Load Condition”

Set a search alert
Also matching:1 journal
Research ArticleOpen accessIn the abstractThe Determination of the Tunnel Structure Loads Through the Analysis of the Interaction between the Void and the Support Using the Convergence-Confinement MethodPierpaolo OresteThe evaluation of the load acting on a tunnel support is of fundamental importance for the correct dimensioning of the structure when analytical calculation methods are used. The load acting on the support depends on various factors and for this reason its evaluation can appear somewhat complex. One way of evaluating the load acting on a support is to use … …American Journal of Applied Sciences, Vol. 11, Issue 11 · 7 Jan 2015 · 6,812 accessesView PDFCite
Research ArticleOpen accessIn the abstractDYNAMIC MODELING AND GAIN SCHEDULING CONTROL OF A CHIILLED WATER COOLING SYSTEMJun Liu, M. ZaheeruddinA dynamic model of a Chilled Water (ChW) cooling system with a stratified ChW tank was developed. A PI-based Gain Scheduling (GS) control strategy was designed to improve thermal performance of the chiller system. Five different operation strategies were simulated and the energy consumption and cost of operating the system under full load and partial load conditions were compared. The … …Energy Research Journal, Vol. 5, Issue 1 · 15 Oct 2014 · 7,015 accessesView PDFCite
Research ArticleOpen accessIn the abstractCOMPARATIVE STUDY OF DIFFERENT KALMAN FILTER IMPLEMENTATIONS IN POWER SYSTEM STABILITYH. H. Goh, C. W. Tai, Q. S. Chua et al.Voltage stability and voltage collapse issues have in recent years begun to constitute an unpleasant warning to the operational security of power systems. Many techniques have been investigated in order to predict the point of voltage collapse. However, there are still several restrictions due to the insufficiency of current system state information. Accompanied by the commencement of the Phasor Measurement … …American Journal of Applied Sciences, Vol. 11, Issue 8 · 29 May 2014 · 7,197 accessesView PDFCite
Research ArticleOpen accessIn the abstractHydrological and Sediment Transport Simulation to Assess the Impact of Dam Construction in the Mekong River Main ChannelSatoshi Kameyama, Hiroto Shimazaki, Seiichi Nohara et al.The downstream impact of dams is a complex problem in watershed management. In the upper Mekong River watershed and its main channel, dam construction projects were started in the 1950s to meet increasing demands for energy and food production. Dams called the Mekong Cascade were completed on the Mekong River in China, the Manwan Dam in 1996 and the Dachaoshan … …American Journal of Environmental Sciences, Vol. 9, Issue 3 · 29 Jun 2013 · 8,576 accessesView PDFCite
Research ArticleOpen accessIn the abstractSimulation and Implementation of Quasi Resonant DC-DC ConverterP. Parvathy, N. DevarajanProblem statement: A half-bridge LLC resonant converter with a voltage doubler rectifier has a simple structure and its Zero-Voltage-Switching (ZVS) capability is excellent from zero to full load condition. But conduction loss is more due to high circulating energy thus reducing the system efficiency. Moreover a variable frequency control method makes the control circuits more complicated than those using the … …Journal of Computer Science, Vol. 8, Issue 10 · 29 Aug 2012 · 7,151 accessesView PDFCite
Research ArticleOpen accessIn the abstractMultipath Adaptive Packet Dispersion for Voice ApplicationsJ. Faritha Banu, V. RamachandranProblem statement: The quality of Voice over IP applications is decided by the main factors like network capacity and technologies such as codec type, Packet Loss Concealment (PLC) and Forward Error Correction (FEC). Approach: In MPLS networks multiple Label Switched Paths (LSP) are established between MPLS ingress and egress nodes to enhance the network performance and QoS for subscribers. To … …Journal of Computer Science, Vol. 8, Issue 4 · 27 Jan 2012 · 7,720 accessesView PDFCite
Research ArticleOpen accessIn the abstractMobility and Density Aware AODV Protocol Extension for Mobile Adhoc Networks-MADA-AODVS. Deepa, G.M. Kadhar NawazProblem statement: In this study, we proposed a method to improve the performance of AODV by reducing overhead by adopting a route message propagation mechanism. According to the new scheme, a node will be selected to forward a routing request message if and only if a condition based on its mobility (speed) and number of neighbors is satisfied. If the … …Journal of Computer Science, Vol. 8, Issue 1 · 26 Oct 2011 · 7,288 accessesView PDFCite
Research ArticleOpen accessIn the abstractMicrobial Consortia from Taptapani Hot Water Springs for Mining Effluent TreatmentPoonam Nasipuri, Gauri G. Pandit, Ashoke Ranjan Thakur, Shaon Ray ChaudhuriProblem statement: Soluble sulfate load in effluent is a crucial problem from mining industries. The study involved isolation of efficient Sulfate Reducing Bacterial (SRB) consortium from hot water spring for bioremediatrion of sulfate contaminated waste water. Approach: The enriched bacterial consortium was isolated in medium DSMZ 16695. The sulfate reduction efficiency was measured by turbidometric method. The Km and Rmax … …Current Research in Microbiology, Vol. 1, Issue 2 · 31 May 2011 · 8,463 accessesView PDFCite
Research ArticleOpen accessIn the abstractImpact of Bulldozer's Engine Load Factor on Fuel Consumption, CO2 Emission and CostVladislav Kecojevic, Dragan KomljenovicProblem statement: Bulldozers consume a large amount of diesel fuel and consequently produce a significant quantity of CO2. Environmental and economic cost issues related to fuel consumption and CO2 emission represent a substantial challenge to the mining industry. Approach: Impact of engine load conditions on fuel consumption and the subsequent CO2 emission and cost was analyzed for Caterpillar bulldozers. Results … …American Journal of Environmental Sciences, Vol. 7, Issue 2 · 26 May 2011 · 9,144 accessesView PDFCite
Research ArticleOpen accessIn the abstractObject Oriented Modeling of Thermostatically Controlled Devices for Cold Load Pick-upAlexandre de Assis Mota, Lia Toledo Moreira Mota, Claudia Cotrim PezzutoProblem statement: During service restoration, the power level at buses can significantly differ from the one presented under steady-state conditions, demanding an amount of electric power significantly higher than the normal load. Hence, their post-outage behavior must be adequately forecasted in order to permit the development of reliable restoration plans, or to avoid inadequate actions that may lead to a … …Journal of Computer Science, Vol. 7, Issue 2 · 25 Feb 2011 · 6,851 accessesView PDFCite