Sign inSubmit
Tips: “quotes” for a phrase · author:Lee · a DOI goes straight to its article

15 results for “Critical clearing time”

Set a search alert
Research ArticleOpen accessIn the keywordsThe Mathematical Model and Simulation of Static Var Compensator in Medium Transmission LinePrechanon KumkratugProblem statement: The Static Var Compensator (SVC) have been widely investigated its effect on transient stability of Single Machine Infinite Bus (SMIB) system. The exact medium transmission line model in power system consists of the series resistance series reactance and shunt capacitance. It is not easy task to obtain the mathematical model of the SVC with the exact medium transmission … …American Journal of Applied Sciences, Vol. 9, Issue 5 · 12 Mar 2012 · 7,393 accessesView PDFCite
Research ArticleOpen accessIn the keywordsThe Mathematical Model of Power System with Thyristor Controlled Series Capacitor in Long Transmission LinePrechanon KumkratugProblem statement: It is becoming increasingly important to fully utilize the existing transmission system assets due to environmental legislation, rights-of-way issues and costs of construction and deregulation policies that introduced in recent years. The Thyristor Controlled Series Capacitor (TCSC) has been proposed for the better control power flow and dynamic performance. The exact long transmission line model consists of the … …American Journal of Applied Sciences, Vol. 9, Issue 5 · 27 Feb 2012 · 6,833 accessesView PDFCite
Research ArticleOpen accessIn the keywordsThe Mathematical Model and Simulation of Thyristor Controlled Series Capacitor in Medium Transmission LinePrechanon KumkratugProblem statement: It is becoming increasingly important to fully utilize the existing transmission system assets due to environmental legislation, rights-of-way issues, costs of construction and deregulation policies that introduced in recent years. The Thyristor Controlled Series Capacitor (TCSC) has been proposed for the better control power flow and dynamic performance. The exact medium transmission line model consists of the resistance … …American Journal of Applied Sciences, Vol. 9, Issue 4 · 9 Feb 2012 · 7,718 accessesView PDFCite
Research ArticleOpen accessIn the keywordsThe Effect of the Static Var Compensator and R/X Ratio of Short Transmission Line on Transient Stability of Single Machine Infinite Bus SystemPrechanon KumkratugProblem statement: It is becoming increasingly important to fully utilize the existing transmission system assets due to environmental legislation, rights-of-way issues and costs of construction and deregulation policies that introduced in recent years. The Static Var Compensator (SVC) has been proposed for the better control power flow and dynamic performance. The exact short transmission line model consists of the resistance … …American Journal of Applied Sciences, Vol. 9, Issue 4 · 7 Feb 2012 · 6,984 accessesView PDFCite
Research ArticleOpen accessIn the keywordsThe Effect of Thyristor Controlled Series Capacitor on Transient Stability of Single Machine Infinite Bus System with the Exact Short Transmission Line ModelPrechanon KumkratugProblem statement: It is becoming increasingly important to fully utilize the existing transmission system assets due to environmental legislation, rights-of-way issues, costs of construction and deregulation policies that were introduced in recent years. The Thyristor Controlled Series Capacitor (TCSC) has been proposed for better control power flow and dynamic performance. The exact short transmission line model consists of the resistance … …American Journal of Applied Sciences, Vol. 9, Issue 3 · 2 Feb 2012 · 7,466 accessesView PDFCite