Thermal assessments for laminar flow in an isothermal wall square channel over downstream Reformed-V (RV) and Reformed-Double-V (RDV) generators inserted diagonally are presented numerically in three dimensional. The RV and RDV are designed to comfort for forming and installing in the heat exchanger channel. The effect of RV and RDV height is investigated in terms of blockage ratio, b/H, BR = 0.05-0.30 for Reynolds number based on the hydraulic diameter of the square channel, Re = 100-1200. The SIMPLE algorithm, finite volume method and the periodic condition are used in the current computational domain. The mathematical results show that the uses of RV and RDV provide higher heat transfer rate than the smooth square channel with no generators. The RV gives higher on both heat transfer rate and friction factor values than the RDV case for all BR and Re values. The maximum heat transfer rate and friction factor are found around 20.5 and 420 times over the smooth square channel, respectively, at BR = 0.30 for RV case. The optimum thermal enhancement factor, TEF, is found at BR = 0.1, Re = 2000 around 2.95 for RDV case.

Licence and reuse

Open access. This article is licensed under a Creative Commons Attribution 3.0 Licence (CC BY 3.0), as printed on the article, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original authors and the source. No permission is needed.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Jedsadaratanachai, W. & Boonloi, A. (2014). Thermal Performance Assessment for Laminar Forced Convection with Downstream Reformed-V and Reformed-Double-V Generators. Journal of Mathematics and Statistics, 10(4), 426–435. https://doi.org/10.3844/jmssp.2014.426.435

Licence
CC BY 3.0
Issue
Volume 10, Issue 4
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
Thermal Performance Assessment for Laminar Forced Convection with Downstream Reformed-V and Reformed-Double-V GeneratorsJournal of Mathematics and Statistics · Volume 10, Issue 4 · pp. 426–435 · CC BY 3.0Download