Sign inSubmit
computersciencejournal.org is not ours. This journal is published only at thescipub.com/jcs. Report a suspicious emailcomputersciencejournal.org is not ours · Report
ArticleMetrics
Research Article · Open access · Published 13 August 2026

Explainable MedAttn-ResNet50 for Automated Kidney Tumor Classification from CT Images With Grad-CAM Visualization

D. Vetrithangam1, Pramod Kumar2, Shilpasree S.3, Akanksha Kulkarni4, Gara Jaya Raju5, Aswathy S Nair6, Subramanian Selvakumar7 & Puneet Kumar1

Journal of Computer Science, Volume 22, Issue 8, pp. 2456–2467 · doi.org/10.3844/jcssp.2026.2456.2467

1,120 accesses616 downloads0 citations (Crossref)Metrics
Cite Check for updates

Abstract

Kidney tumor classification from CT imaging remains challenging due to CT-specific intensity variations, tumor heterogeneity, and limited clinically meaningful interpretability in existing deep learning models. To address these limitations, we propose an Explainable MedAttn-ResNet50 framework that integrates radiology-driven preprocessing, multi-scale feature extraction, and medical attention mechanisms within a unified architecture. The preprocessing pipeline applies radiology-inspired intensity normalization, contrast enhancement, and data augmentation to preserve diagnostically relevant tissue contrast. A Multi-Scale Feature Extraction Module (MSFEM) captures tumors of varying shapes and sizes, improving robustness to heterogeneous cases, while spatial, channel, and medical knowledge–gated attention guides the network to focus on anatomically relevant regions. Grad-CAM is applied at deeper layers to generate high-resolution visual explanations and was assessed qualitatively via representative overlays. The model was trained and evaluated on 10,000 CT images and achieved 99.40% accuracy, with 99.80% sensitivity, 99.00% specificity, and 0.993 AUC, outperforming several baseline architectures. These results demonstrate that the proposed method improves predictive performance while providing clinically aligned interpretability for kidney tumor classification.

Licence and reuse

Open access. This article is licensed under a Creative Commons Attribution 4.0 International Licence (CC BY 4.0), as printed on the article, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original authors and the source. No permission is needed.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Vetrithangam, D., Kumar, P., S., S., Kulkarni, A., Raju, G. J., Nair, A. S. & Selvakumar, S. (2026). Explainable MedAttn-ResNet50 for Automated Kidney Tumor Classification from CT Images With Grad-CAM Visualization. Journal of Computer Science, 22(8), 2456–2467. https://doi.org/10.3844/jcssp.2026.2456.2467

Licence
CC BY 4.0
Issue
Volume 22, Issue 8
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
Explainable MedAttn-ResNet50 for Automated Kidney Tumor Classification from CT Images With Grad-CAM VisualizationJournal of Computer Science · Volume 22, Issue 8 · pp. 2456–2467 · CC BY 4.0Download