Sign inSubmit
computersciencejournal.org is not ours. This journal is published only at thescipub.com/jcs. Report a suspicious emailcomputersciencejournal.org is not ours · Report
ArticleArticle metrics
Research Article · Free to read · Published 8 May 2014

SOPC BASED WIRELESS REMOTE PATIENT MONITORING USING ULTRA LIGHTWEIGHT CRYPTOGRAPHY

A. Arun1 & P. Nirmal Kumar1

Journal of Computer Science, Volume 10, Issue 10, pp. 1924–1928 · doi.org/10.3844/jcssp.2014.1924.1928

7,194 accesses4,650 downloads1 citations (Crossref)Journal metrics
Cite Check for updates

Abstract

Remote Patient Monitoring (RPM) provides flexible and powerful patient surveillance through wearable devices at anytime and anywhere. This can be achieved by using a Body Sensor Network (BSN), which is deployed on a human body for monitoring the healthcare. The mobile healthcare management with increased feasibility and handiness introduced several noteworthy challenges for the provider, policy makers, patient and hospitals. A significant challenge is to provide round-the-clock healthcare services to those patients who require it via wearable medical devices. In addition to this, the sensors collect the personal medical data where the security and privacy are important components in RPM. As a result, one of the most significant and challenging concern to deal with is how to secure the personal information of the patients and to eliminate their privacy issue. This study presents System on Programmable Chip (SoPC) implementation of Remote Patient Monitoring System (RPM) with Ultra Lightweight algorithms for security issues. Humming Bird 2 (HB-2), PRESENT and HIGHT algorithms were implemented since the wearable medical devices require fewer areas to achieve portability. The comparison results shows that Degree of Confusion of HB-2 is 50.43 which outstand the other, the efficiency of the entire algorithm implemented in SoPC are higher comparing with conventional Field Programmable Gate Array (FPGA) implementation. The comparison was extended and in Particular, power and area consumption of HB-2 is less than PRESENT and HIGHT algorithm, which is more suitable for RPM devices.

Licence and reuse

Free to read. This article carries the publisher’s copyright, as printed on it: © 2014 Science Publications. It is free to read; ask us before reusing it.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Arun, A. & Kumar, P. N. (2014). SOPC BASED WIRELESS REMOTE PATIENT MONITORING USING ULTRA LIGHTWEIGHT CRYPTOGRAPHY. Journal of Computer Science, 10(10), 1924–1928. https://doi.org/10.3844/jcssp.2014.1924.1928

Licence
© Science Publications
Issue
Volume 10, Issue 10
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
SOPC BASED WIRELESS REMOTE PATIENT MONITORING USING ULTRA LIGHTWEIGHT CRYPTOGRAPHYJournal of Computer Science · Volume 10, Issue 10 · pp. 1924–1928 · © Science PublicationsDownload