Sign inSubmit
computersciencejournal.org is not ours. This journal is published only at thescipub.com/jcs. Report a suspicious emailcomputersciencejournal.org is not ours · Report
ArticleArticle metrics
Research Article · Free to read · Published 31 July 2009

Anomaly Detection in Electroencephalogram Signals Using Unconstrained Minimum Average Correlation Energy Filter

Aini Hussain, Rosniwati Ghafar, Salina Abdul Samad & Nooritawati Md Tahir1

Journal of Computer Science, Volume 5, Issue 7, pp. 501–506 · doi.org/10.3844/jcssp.2009.501.506

7,326 accesses5,238 downloads3 citations (Crossref)Journal metrics
Cite Check for updates

Abstract

Problem statement: Electroencepharogram (EEG) is an extremely complex signal with very low signal to noise ratio and these attributed to difficulty in analyzing the signal. Hence for detecting abnormal segment, a distinctive method is required to train the technologist to distinguish the anomalous in EEG data. The objective of this study was to create a framework to analyze EEG signals recorded from epileptic patients by evaluating the potential of UMACE filter to detect changes in single-channel EEG data during routine epilepsy monitoring. Approach: Normally, the peak to side lobe ratio (PSR) of a UMACE filter was employed as an indicator if a test data is similar to an authentic class or vice versa, however in this study, the consistent changes of the correlation output known as Region Of Interest (ROI) was plotted and monitored. Based on this approach, a novel method to analyze and distinguish variances in scalp EEG as well as comparing both normal and abnormal regions of the patient’s EEG was assessed. The performance of the novelty detection was examined based on the onset and end time of each seizure in the ROI plot. Results: Results showed that using ROI plot of variances one can distinguish irregularities in the EEG data. The advantage of the proposed technique was that it did not require large amount of data for training. Conclusion: As such, it was feasible to perform seizure analysis as well as localizing seizure onsets. In short, the technique can be used as a guideline for faster diagnosis in a lengthy EEG recording.

Licence and reuse

Free to read. This article carries the publisher’s copyright, as printed on it: © 2009 Science Publications. It is free to read; ask us before reusing it.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Hussain, A., Ghafar, R., Samad, S. A. & Tahir, N. M. (2009). Anomaly Detection in Electroencephalogram Signals Using Unconstrained Minimum Average Correlation Energy Filter . Journal of Computer Science, 5(7), 501–506. https://doi.org/10.3844/jcssp.2009.501.506

Licence
© Science Publications
Issue
Volume 5, Issue 7
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
Anomaly Detection in Electroencephalogram Signals Using Unconstrained Minimum Average Correlation Energy FilterJournal of Computer Science · Volume 5, Issue 7 · pp. 501–506 · © Science PublicationsDownload