Sign inSubmit
ArticleArticle metrics
Research Article · Free to read · Published 31 October 2010

Arm Movement Recorder

Jakkrapun Chuanasa1 & Szathys Songschon1

Energy Research Journal, Volume 1, Issue 2, pp. 126–130 · doi.org/10.3844/erjsp.2010.126.130

7,762 accesses4,590 downloads0 citations (Crossref)Journal metrics
Cite Check for updates

Abstract

Problem statement: Human arm movement is widely studied nowadays. Some movements of arm are performed frequently in everyday life. Devices that can record the path of movement are important in studying human arm gesture. Approach: This project was performed the five degree-of-freedom exoskeleton that was designed and constructed to observe position and orientation values of various movement in x-y-z coordinates of human arm. All joints of the exoskeleton were attached with potentiometers for tracking a human arm trajectory. A dedicated computer with a software application, LabVIEW, obtained the data from arm movement and translated to the end effector coordinate. A calibration method for the exoskeleton was proposed for a particular path, a circle. A value correction for the chosen path was introduced in this calibration process and error of root mean square was used as performance index to measure radial error and geometric error of the exoskeleton. Results: Experiments with a human arm for executing repetitive tasks were performed to study. There were two sets of experiments. With correction factor applied to both experiments, the average Error of Root Mean Square (ERMS) reduced drastically. Conclusion: With the correction factor, this device could use to record particaular movement of human's arm with small error.

Licence and reuse

Free to read. This article carries the publisher’s copyright, as printed on it: © 2010 Science Publications. It is free to read; ask us before reusing it.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Chuanasa, J. & Songschon, S. (2010). Arm Movement Recorder. Energy Research Journal, 1(2), 126–130. https://doi.org/10.3844/erjsp.2010.126.130

Licence
© Science Publications
Issue
Volume 1, Issue 2
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
Arm Movement RecorderEnergy Research Journal · Volume 1, Issue 2 · pp. 126–130 · © Science PublicationsDownload