Sign inSubmit
ArticleArticle metrics
Research Article · Free to read · Published 1 January 2013

Sulfur Dioxide and Volatile Organic Compound Exposure to a Community in Texas City, Texas Evaluated Using Aermod and Empirical Monitoring Data

Joyce A. Chen1, Andrew R. Zapata1, Anders J. Sutherland1, David R. Molmen1, Brittany S. Chow1, Lauren E. Wu1, Paul E. Rosenfeld1 & Rob C. Hesse1

American Journal of Environmental Sciences, Volume 8, Issue 6, pp. 622–632 · doi.org/10.3844/ajessp.2012.622.632

8,715 accesses7,567 downloads2 citations (Crossref)Journal metrics
Cite Check for updates

Abstract

According to emissions data reported to the United States Environmental Protection Agency (USEPA) and the Texas Commission on Environmental Quality (TCEQ), the BP Products North America Inc. (BP) Texas City Refinery is the worst polluter of all the industries in Texas City and is one of the worst polluting refineries in the country. The facility has reported releasing substantial emissions of Sulfur Dioxide (SO2) and Volatile Organic Compounds (VOCs). Air dispersion modeling of the emissions from the facility can be used to assess contamination in the community surrounding the BP Texas City Refinery. In the present study, air dispersion modeling of SO2 and VOCs was performed using AERMOD, the EPA-preferred regulatory dispersion model, to determine the impact of BP’s contribution to local air pollution on residents of Texas City and La Marque. SO2 emissions reported to be released by the facility were modeled using AERMOD and it was determined that geographical locations inside this plume experienced ambient air concentrations of SO2 meeting or exceeding 50 micrograms per cubic meter (µg/m3) in 2009 and 2010. Data collected by six active SO2 air monitors located in Texas City support the air dispersion modeling results. Additional modeling was conducted for VOCs emitted by the facility in 2010. The AERMOD analysis of SO2 concentrations in and around the BP facility produced results consistent with data collected by the air monitoring network in Texas City. This confirms the accuracy of AERMOD’s estimations and its reliability as an emissions modeling tool. VOC concentrations available for analysis from the air monitoring network in Texas City are extremely limited in terms of the quantity of VOCs sampled for. This evidence affirms the ability of AERMOD to demonstrate comprehensive contaminant impacts that surpass the ability of the current air monitoring network.

Licence and reuse

Free to read. This article carries the publisher’s copyright, as printed on it: © 2012 Science Publications. It is free to read; ask us before reusing it.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Chen, J. A., Zapata, A. R., Sutherland, A. J., Molmen, D. R., Chow, B. S., Wu, L. E., Rosenfeld, P. E. & Hesse, R. C. (2012). Sulfur Dioxide and Volatile Organic Compound Exposure to a Community in Texas City, Texas Evaluated Using Aermod and Empirical Monitoring Data. American Journal of Environmental Sciences, 8(6), 622–632. https://doi.org/10.3844/ajessp.2012.622.632

Licence
© Science Publications
Issue
Volume 8, Issue 6
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
Sulfur Dioxide and Volatile Organic Compound Exposure to a Community in Texas City, Texas Evaluated Using Aermod and Empirical Monitoring DataAmerican Journal of Environmental Sciences · Volume 8, Issue 6 · pp. 622–632 · © Science PublicationsDownload