Reduction of Radiation Effects in Biomedical Imaging Detectors by Technology Change
Essesse Songa Auguste1, Wembe Tafo Evariste1, Madinatou Salomon2 & Belinga Aboudou Jean1 Show affiliations
- University of Douala, Cameroon
- University of Yaoundé , Cameroon
American Journal of Engineering and Applied Sciences, Volume 14, Issue 3, pp. 364–370 · doi.org/10.3844/ajeassp.2021.364.370
Abstract
Silicon is a preferred material in the design of medical imaging detectors. It enables reliable and inexpensive detectors to be produced. However, the operation of this material is compromised when irradiated with high radiation of more than 5 ×1014 particles/cm2of high energy neutrons. The defects caused transform the electrical properties. Therefore, this loss of information compromises the reconstruction of important events. This research paper aims to make a scientific contribution to the reduction of this radiation effects. The proposed solution is obtained by changing the silicon material generally used to design the detectors by a carbon nanotube material. The use of carbon nanotube material allows the detector to reduce the effects of radiation and leakage currents. A particular observation was made on the linear attenuation coefficient μ, the radiation length X0 and the width of the forbidden band Eg. Our results show the best characteristics for a carbon nanotube material compared to silicon. For a cross thermal section equal to σSi = σc = 2 ×10-3b ,the carbon linear attenuation coefficient is great her than the silicon (μSi = 9.979 ×10-5cm-1 <μC = 3.533 ×10-4cm-1), For a maximum effective cross section of equal diffusion σC = 1009 ×10-3b, (μSi = 0.503 ×10-3 cm-1 <μC = 1.732 ×10-3 cm-1), for a minimum effective cross section of equal diffusion σSi = σC = 10.09 ×10-3b, μSi = 0.503 ×10-3 cm-1 <μC = 1.732 ×10-3 cm-1. X0si = 22.009 g/cm2 and X0c= 42.969 g/cm2, Egsi= 1.2e.V and Egsi= 5.5e.V. From these results, the carbon material has an attenuation coefficient at least three times higher than that of the silicon material.
Licence and reuse
Open access. This article is licensed under a Creative Commons Attribution 4.0 International Licence (CC BY 4.0), as printed on the article, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original authors and the source. No permission is needed.
How to reuse this articleResponses (0)
About this article
Auguste, E. S., Evariste, W. T., Salomon, M. & Jean, B. A. (2021). Reduction of Radiation Effects in Biomedical Imaging Detectors by Technology Change. American Journal of Engineering and Applied Sciences, 14(3), 364–370. https://doi.org/10.3844/ajeassp.2021.364.370
- Licence
- CC BY 4.0
- Issue
- Volume 14, Issue 3
- Policies
- Editorial independenceUse of generative AIData availabilityAppeals and complaints
- Version
- Version of record