Sign inSubmit
ArticleMetrics
Research Article · Open access · Published 17 July 2021

Reduction of Radiation Effects in Biomedical Imaging Detectors by Technology Change

Essesse Songa Auguste1, Wembe Tafo Evariste1, Madinatou Salomon2 & Belinga Aboudou Jean1

American Journal of Engineering and Applied Sciences, Volume 14, Issue 3, pp. 364–370 · doi.org/10.3844/ajeassp.2021.364.370

6,987 accesses3,357 downloads0 citations (Crossref)Metrics
Cite Check for updates

Abstract

Silicon is a preferred material in the design of medical imaging detectors. It enables reliable and inexpensive detectors to be produced. However, the operation of this material is compromised when irradiated with high radiation of more than 5 &times;1014 particles/cm2of high energy neutrons. The defects caused transform the electrical properties. Therefore, this loss of information compromises the reconstruction of important events. This research paper aims to make a scientific contribution to the reduction of this radiation effects. The proposed solution is obtained by changing the silicon material generally used to design the detectors by a carbon nanotube material. The use of carbon nanotube material allows the detector to reduce the effects of radiation and leakage currents. A particular observation was made on the linear attenuation coefficient μ, the radiation length X0 and the width of the forbidden band Eg. Our results show the best characteristics for a carbon nanotube material compared to silicon. For a cross thermal section equal to &sigma;Si = &sigma;c = 2 &times;10-3b ,the carbon linear attenuation coefficient is great her than the silicon (&mu;Si = 9.979 &times;10-5cm-1 <&mu;C = 3.533 &times;10-4cm-1), For a maximum effective cross section of equal diffusion &sigma;C = 1009 &times;10-3b, (&mu;Si = 0.503 &times;10-3 cm-1 <&mu;C = 1.732 &times;10-3 cm-1), for a minimum effective cross section of equal diffusion &sigma;Si = &sigma;C = 10.09 &times;10-3b, &mu;Si = 0.503 &times;10-3 cm-1 <&mu;C = 1.732 &times;10-3 cm-1. X0si = 22.009 g/cm2 and  X0c= 42.969 g/cm2,  Egsi= 1.2e.V and  Egsi= 5.5e.V. From these results, the carbon material has an attenuation coefficient at least three times higher than that of the silicon material.

Licence and reuse

Open access. This article is licensed under a Creative Commons Attribution 4.0 International Licence (CC BY 4.0), as printed on the article, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original authors and the source. No permission is needed.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Auguste, E. S., Evariste, W. T., Salomon, M. & Jean, B. A. (2021). Reduction of Radiation Effects in Biomedical Imaging Detectors by Technology Change. American Journal of Engineering and Applied Sciences, 14(3), 364–370. https://doi.org/10.3844/ajeassp.2021.364.370

Licence
CC BY 4.0
Issue
Volume 14, Issue 3
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
Reduction of Radiation Effects in Biomedical Imaging Detectors by Technology ChangeAmerican Journal of Engineering and Applied Sciences · Volume 14, Issue 3 · pp. 364–370 · CC BY 4.0Download