Sign inSubmit
ArticleMetrics
Research Article · Open access · Published 25 March 2014

THE USE OF DIFFERENT LEVELS OF MULTI-ROOM MODELING APPROACH-APPLICATION TO BUILDING POLLUTION TRANSPORT AND EFFICIENCY OF OFF-HOUR VENTILATION

Ahmed Cherif Megri1

American Journal of Engineering and Applied Sciences, Volume 7, Issue 1, pp. 88–98 · doi.org/10.3844/ajeassp.2014.88.98

7,768 accesses5,630 downloads3 citations (Crossref)Metrics
Cite Check for updates

Abstract

Several building simulation programs have been developed for design, analysis and prediction of the distribution of temperature, airflow and heat transfer between inside and outside of a building and/or between different zones of the same building. These programs are categorized as mono-zone models, multi-room models, zonal models, Computational Fluid Dynamics (CFD) models and multi-zone models. The number of computer programs continues to increase, each reflecting different objectives and concerns. Some of these computer programs are dedicated to research and others to design and auditing. However, none of the existing computer programs is able to translate automatically various steps of the design process as actually performed by design Architectural Engineering firms. This study addresses different levels of multi-room simulation programs developed through the last four decades. Two case studies using multi-room programs have been exposed to illustrate the appropriate use of various levels of this approach for design and analysis.

Licence and reuse

Open access. This article is licensed under a Creative Commons Attribution 3.0 Licence (CC BY 3.0), as printed on the article, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original authors and the source. No permission is needed.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Megri, A. C. (2014). THE USE OF DIFFERENT LEVELS OF MULTI-ROOM MODELING APPROACH-APPLICATION TO BUILDING POLLUTION TRANSPORT AND EFFICIENCY OF OFF-HOUR VENTILATION. American Journal of Engineering and Applied Sciences, 7(1), 88–98. https://doi.org/10.3844/ajeassp.2014.88.98

Licence
CC BY 3.0
Issue
Volume 7, Issue 1
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
THE USE OF DIFFERENT LEVELS OF MULTI-ROOM MODELING APPROACH-APPLICATION TO BUILDING POLLUTION TRANSPORT AND EFFICIENCY OF OFF-HOUR VENTILATIONAmerican Journal of Engineering and Applied Sciences · Volume 7, Issue 1 · pp. 88–98 · CC BY 3.0Download