Performance Analysis and Components Irreversiblities of a (25 MW) Gas Turbine Power Plant Modeled with a Spray Cooler

Fidelis Ibiang Abam1, Ikpi U. Ugot1 & Dodeye Ina Igbong1

American Journal of Engineering and Applied Sciences, Volume 5, Issue 1, pp. 35–41 · doi.org/10.3844/ajeassp.2012.35.41

9,379 accesses10,133 downloads22 citations (Crossref)Metrics
Cite Check for updates

Abstract

In this study the effect of inlet air cooling system and components irreversibilities on the performance of an active 25MW gas turbine power plant was investigated. The objective of this study was to establish the potential benefits of improving the performance of the current gas turbine plant into a more advanced cycle with high efficiency and power output through inlet air cooling. Problem statement: The hypothesis was that the low performance of the gas turbine plant was caused by high ambient temperature, the use of spray cooler was adopted to bring the air condition temperature close to ISO condition. Approach: In this study, performance characteristics were determined for a set of actual operational conditions including ambient temperature, relative humidity, turbine inlet temperature and pressure ratio. Results: The results obtained show that the use of a spray cooler on the existing gas turbine cycle gives a better thermal efficiency and less irreversibility rate in the components system and the entire plant. The power output of the gas turbine plant with spray cooler was found to have increased by over 7%, accompanied by 2.7% increase in machine efficiency with a reduction in specific fuel consumption of 2.05 and 10.03% increase in the energy of exhaust. Furthemore, a 0.32% reduction in the total irreversibility rate of the plant for the cooled cycle was obtained and a 0.39, 0.29 and 0.17% reduction in the irreversibility rate of compressor, turbine and combustion chamber respectively, were also obtained. Conclusion: The results show that retrofitting the existing gas turbine plant with inlet air cooling system gives a better system performance and may prove to be an attractive investment opportunity.

Licence and reuse

Open access. This article is licensed under a Creative Commons Attribution 3.0 Licence (CC BY 3.0), as printed on the article, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original authors and the source. No permission is needed.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Abam, F. I., Ugot, I. U. & Igbong, D. I. (2012). Performance Analysis and Components Irreversiblities of a (25 MW) Gas Turbine Power Plant Modeled with a Spray Cooler. American Journal of Engineering and Applied Sciences, 5(1), 35–41. https://doi.org/10.3844/ajeassp.2012.35.41

Licence
CC BY 3.0
Issue
Volume 5, Issue 1
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
Performance Analysis and Components Irreversiblities of a (25 MW) Gas Turbine Power Plant Modeled with a Spray CoolerAmerican Journal of Engineering and Applied Sciences · Volume 5, Issue 1 · pp. 35–41 · CC BY 3.0Download