Sign inSubmit
ArticleMetrics
Research Article · Free to read · Published 30 September 2010

Natural Ventilation of Indoor Air Temperature: A Case Study of the Traditional Malay House in Penang

Ahmad Sanusi Hassan1 & Mahyuddin Ramli1

American Journal of Engineering and Applied Sciences, Volume 3, Issue 3, pp. 521–528 · doi.org/10.3844/ajeassp.2010.521.528

11,956 accesses9,887 downloads34 citations (Crossref)Metrics
Cite Check for updates

Abstract

Problem statement: It was the aim of the study to analyze the level of performance of natural air ventilation with a case study of the traditional Malay house in Penang, Malaysia. This study provided information on the architectural design in relation to natural air ventilation. It promoted passive design in contrast to most housing design which has poor natural air ventilation because the design was orientated to energy consumption that slightly more than one third of the electric energy was used for heating, ventilating and air conditioning systems. Approach: This analysis used quantitative method which measured temperature, humidity and wind speed of the traditional house. The result indicated the level of performance of cross air ventilation and stack effect. Results: The analysis showed that the traditional house has a design integrated with natural air ventilation system. The indoor house temperature and relative humidity had slightly lower than its outdoor area. However, the indoor area had lower wind speed level than the outdoor area. Conclusion: The study showed that maximum openings on the building walls created high air intakes outside the house to give poor performance of stack effect. The design had more emphasis to cross air ventilation.

Licence and reuse

Free to read. This article carries the publisher’s copyright, as printed on it: © 2010 Science Publications. It is free to read; ask us before reusing it.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Hassan, A. S. & Ramli, M. (2010). Natural Ventilation of Indoor Air Temperature: A Case Study of the Traditional Malay House in Penang . American Journal of Engineering and Applied Sciences, 3(3), 521–528. https://doi.org/10.3844/ajeassp.2010.521.528

Licence
© Science Publications
Issue
Volume 3, Issue 3
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
Natural Ventilation of Indoor Air Temperature: A Case Study of the Traditional Malay House in PenangAmerican Journal of Engineering and Applied Sciences · Volume 3, Issue 3 · pp. 521–528 · © Science PublicationsDownload