Effect of Confinement on the Axial Performance of Fibre Reinforced Polymer Wrapped RC Column
A. Rajasekaran1, P.N. Raghunath1 & K. Suguna1 Show affiliations
- Annamalai University, India
American Journal of Engineering and Applied Sciences, Volume 1, Issue 2, pp. 110–117 · doi.org/10.3844/ajeassp.2008.110.117
Abstract
The combined effect of internal steel ties and external FRP wrap was investigated using nine reinforced concrete columns with varying thickness of external wrap. The load, deflection and lateral expansions were studied at yield state and ultimate state. The results from the experimental investigations were used for performing a multi-variate linear regression analysis incorporating the contribution of tie spacing as a term. The predictions of the regression equation agreed well with the experimental results and showed sensitive difference in compressive strength for changes in tie spacing.
Licence and reuse
Free to read. This article carries the publisher’s copyright, as printed on it: © 2008 Science Publications. It is free to read; ask us before reusing it.
How to reuse this articleResponses (0)
About this article
Rajasekaran, A., Raghunath, P. & Suguna, K. (2008). Effect of Confinement on the Axial Performance of Fibre Reinforced Polymer Wrapped RC Column. American Journal of Engineering and Applied Sciences, 1(2), 110–117. https://doi.org/10.3844/ajeassp.2008.110.117
- Licence
- © Science Publications
- Issue
- Volume 1, Issue 2
- Policies
- Editorial independenceUse of generative AIData availabilityAppeals and complaints
- Version
- Version of record