Sensitive and Rapid Detection of Sulfate-Reducing Bacteria in Jet Fuel by Loop-Mediated Isothermal Amplification Combined with Lateral Flow Dipstick
Zezhen Li1, Yun Xiong1, Peng Zhu2 & Hailong Huang3 Show affiliations
- Logistical Engineering University, China
- Sinopec Zhenhai Refining & Chemical Corps Room, China
- Ningbo University, China
American Journal of Biochemistry and Biotechnology, Volume 14, Issue 2, pp. 117–123 · doi.org/10.3844/ajbbsp.2018.117.123
Abstract
The existence of Sulfate-Reducing Bacteria (SRB) is one of the significant reasons for the Microbially Influenced Corrosion (MIC) of jet fuel. Especially for the jet fuel stored by military, since jet fuel is stored in the tank for a long time, some oxygen-consuming bacteria such as Amorphotheca resinae and Bacillus Cohn can consume oxygen and generate organic acids at the oilwater interface of the tank bottom. This causes anaerobic SRB flourish in fuel tanks. In this study, a loop-mediated isothermal amplification (LAMP) combined with a chromatographic Lateral Flow Dipstick (LFD) assay was established to detect the SRB. Four groups of LAMP primers were designed and synthesized to target dsrB (dissimilatory sulfite reductase β-subunit) genes in SRB.LAMP-LFD can detect 121 fg/µL of SRB DNA within 35 min. The detection limit of this method is 1000 times more sensitive than the conventional PCR and shortens the detection time greatly. This method is negative for other eight common bacteria species in jet fuel, indicating that the method has high specificity. In summary, this method can be used to detect the presence of SRB in jet fuel.
Licence and reuse
Open access. This article is licensed under a Creative Commons Attribution 3.0 Licence (CC BY 3.0), as printed on the article, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original authors and the source. No permission is needed.
How to reuse this articleResponses (0)
About this article
Li, Z., Xiong, Y., Zhu, P. & Huang, H. (2018). Sensitive and Rapid Detection of Sulfate-Reducing Bacteria in Jet Fuel by Loop-Mediated Isothermal Amplification Combined with Lateral Flow Dipstick. American Journal of Biochemistry and Biotechnology, 14(2), 117–123. https://doi.org/10.3844/ajbbsp.2018.117.123
- Licence
- CC BY 3.0
- Issue
- Volume 14, Issue 2
- Policies
- Editorial independenceUse of generative AIData availabilityAppeals and complaints
- Version
- Version of record
