Characteristics of Lipoprotein Peak x Eluted from a Column with the Eluent of High-magnesium Ion Concentration in Lipoprotein Analysis Using the Cation-exchange Chromatography
Yuji Hirowatari1, Hiroshi Yoshida2, Yutaka Ogura1, Hidekastu Yanai2, Hideo Kurosawa2 & Norio Tada2 Show affiliations
- Jikei University School of Medicine, Japan
- University Hospital, Japan
American Journal of Biochemistry and Biotechnology, Volume 1, Issue 3, pp. 153–159 · doi.org/10.3844/ajbbsp.2005.153.159
Abstract
The new lipoprotein analysis method using a cation-exchange chromatography, which contains a sulfopropyl-ligand column and two magnesium ion-containing eluents was previously reported. This method can separate serum lipoproteins on the column gel with a magnesium ion concentration gradient and high-density lipoprotein (HDL), low-density lipoprotein (LDL), very-low-density lipoprotein (VLDL) and an unspecified lipoprotein peak are eluted in order from the column. We have now characterized the unspecified lipoproteins, designated peak x, which is last eluted from the column with the eluent of high-magnesium ion concentration. The peak x was small size chylomicron fraction with a part of VLDL. Furthermore, the cholesterol values in the peak x were significantly correlated with remnant-like particle (RLP)-cholesterol values. The peak x separated from a hyperlipidemic patient included apolipoprotein B-100, B-48, E, A-1 and Cs (C-I, C-II, C-III) and its composition of free cholesterol, cholesteryl esters, triglyceride (TG) and phospholipids in total lipids were 6, 15, 66 and 13%, respectively. These results suggest that a major part of the lipoprotein peak X may be composed of remnants of chylomicron and VLDL, but it remains to be elucidated.
Licence and reuse
Free to read. This article carries the publisher’s copyright, as printed on it: © 2005 Science Publications. It is free to read; ask us before reusing it.
How to reuse this articleResponses (0)
About this article
Hirowatari, Y., Yoshida, H., Ogura, Y., Yanai, H., Kurosawa, H. & Tada, N. (2005). Characteristics of Lipoprotein Peak x Eluted from a Column with the Eluent of High-magnesium Ion Concentration in Lipoprotein Analysis Using the Cation-exchange Chromatography. American Journal of Biochemistry and Biotechnology, 1(3), 153–159. https://doi.org/10.3844/ajbbsp.2005.153.159
- Licence
- © Science Publications
- Issue
- Volume 1, Issue 3
- Policies
- Editorial independenceUse of generative AIData availabilityAppeals and complaints
- Version
- Version of record