Sign inSubmit
ArticleMetrics
Research Article · Open access · Published 24 May 2018

Novel LC-MS/MS Method for CJ-023423 (Grapiprant) Determination in Rabbit Plasma

Elena Baralla1, Virginia De Vito1, Maria Vittoria Varoni1, Mario Giorgi2 & Maria Piera Demontis1

American Journal of Animal and Veterinary Sciences, Volume 13, Issue 2, pp. 45–50 · doi.org/10.3844/ajavsp.2018.45.50

7,988 accesses6,175 downloads2 citations (Crossref)Metrics
Cite Check for updates

Abstract

Grapiprant is a new anti-inflammatory drug that preferentially targets the EP4 receptor of prostaglandin E2 limiting the wide range of adverse effects caused by the classical non steroideal anti-inflammatory drugs. The aim of this study was to develop and validate a new, simple, sensitive and rapid Liquid Chromatography tandem Mass Spectrometry method (LC-MS/MS) in order to quantify this novel drug in plasma. The method involved a simple liquid extraction followed by a gradient elution with formic acid 0.2% in water and acetonitrile in reverse phase chromatography. The method was validated according to international guidelines determining selectivity, linearity, sensitivity, recovery, matrix effect and precision. Linearity was obtained over a range of 5-1000 ng mL-1. The obtained Limit of Quantitation (LOQ) and of Determination (LOD) were of 5 and 1.5 ng mL-1 respectively. Extraction recovery was >73% for all the tested concentrations. Matrix effect, expressed as ion suppression, was ≤9%. The intraday and inter-day precision results showed good RSD values. All the validation parameters were satisfactory making this new method an interesting tool for scientists to further investigations on pharmacokinetics parameters. This validated method was applied to assess the pharmacokinetic of grapiprant in one rabbit administered with 0.5 mg kg-1.

Licence and reuse

Open access. This article is licensed under a Creative Commons Attribution 3.0 Licence (CC BY 3.0), as printed on the article, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original authors and the source. No permission is needed.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Baralla, E., De Vito, V., Varoni, M. V., Giorgi, M. & Demontis, M. P. (2018). Novel LC-MS/MS Method for CJ-023423 (Grapiprant) Determination in Rabbit Plasma. American Journal of Animal and Veterinary Sciences, 13(2), 45–50. https://doi.org/10.3844/ajavsp.2018.45.50

Licence
CC BY 3.0
Issue
Volume 13, Issue 2
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
Novel LC-MS/MS Method for CJ-023423 (Grapiprant) Determination in Rabbit PlasmaAmerican Journal of Animal and Veterinary Sciences · Volume 13, Issue 2 · pp. 45–50 · CC BY 3.0Download