Sign inSubmit
ArticleMetrics
Research Article · Open access · Published 10 July 2024

The Impact of XRF-Escape on Energy Resolution of NaI: Tl Scintillation Detectors for Medical Imaging or Gamma-Ray Spectroscopy

Raffaele Scafè1, Marco Puccini2, Rosanna Pellegrini3 & Roberto Pani1

American Journal of Applied Sciences, Volume 21, Issue 1, pp. 28–40 · doi.org/10.3844/ajassp.2024.28.40

5,024 accesses3,098 downloads2 citations (Crossref)Metrics
Cite Check for updates

Abstract

The effect of escape of X-ray fluorescence from scintillator elemental components on the detector energy resolution is investigated from a spectroscopic standpoint, for monolithic and pixelated crystals. Along with these, any other emissions in a given region of interest were also considered. In present spectral evaluations a range of ratios between the areas of the peaks (XRFesc) to (XRFesc + photoelectric) has been a priori set from 0-50%, according to literature indications, by 10% steps. At the upper extremes of these ratio values, maximum worsening in energy resolution values just below 40%, just above 10% and just below 10% have been estimated for the interest regions of Tc-99 and F-18e Cs-137, respectively. The inter-crystal XRF-escape is suggested to be considered among the effects producing image blurring in segmented scintillators due to the spread of events between neighbor pixels

Licence and reuse

Open access. This article is licensed under a Creative Commons Attribution 4.0 International Licence (CC BY 4.0), as printed on the article, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original authors and the source. No permission is needed.

How to reuse this article

Responses (0)

Have a comment on this research? Sign in to respond. Responses are moderated and published with your name and affiliation; the authors are invited to reply. How we use your dataWrite a response

About this article

Cite this article

Scafè, R., Puccini, M., Pellegrini, R. & Pani, R. (2024). The Impact of XRF-Escape on Energy Resolution of NaI: Tl Scintillation Detectors for Medical Imaging or Gamma-Ray Spectroscopy. American Journal of Applied Sciences, 21(1), 28–40. https://doi.org/10.3844/ajassp.2024.28.40

Licence
CC BY 4.0
Issue
Volume 21, Issue 1
Policies
Editorial independenceUse of generative AIData availabilityAppeals and complaints
Version
Version of record
The Impact of XRF-Escape on Energy Resolution of NaI: Tl Scintillation Detectors for Medical Imaging or Gamma-Ray SpectroscopyAmerican Journal of Applied Sciences · Volume 21, Issue 1 · pp. 28–40 · CC BY 4.0Download