Effects of Plastic Wedges on Whole Foot Radiograph in Anteroposterior and Oblique Positions
Poe Lorlorm1, Winit Choiprasert1, Montree Tungjai1 & Suchart Kothan1 Show affiliations
- Department of Radiologic Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand 50200, Thailand
American Journal of Applied Sciences, Volume 14, Issue 4, pp. 511–516 · doi.org/10.3844/ajassp.2017.511.516
Abstract
The whole foot radiography may be taken twice with different exposure parameters. It produces two images in two radiation exposures; one is the metatarsal view of the phalange and the other is a tarsal view. The aim of this study was to study the effects of plastic wedges on whole foot radiography with one radiation exposure. The plastic wedge was developed from plastic wood. Whole foot phantom radiographic imaging was created in anteroposterior and oblique positions with and without plastic wedges mounted on the collimator of an X-ray machine. A radiation imaging plate was used as a transmitted-radiation receptor. The radiation exposure parameter was 54 kilo-voltage at 100 milliamperes for 0.02 sec. The results showed that the resolution of whole foot phantom radiographic imaging in both anteroposterior and oblique positions with plastic wedge mounted on a collimator of an X-ray machine was better than without plastic wedge mounted on collimator. Percentage of Coefficient Variance (%CV) of pixel value on radiographic imaging with plastic wedge mounted on collimator was less than without plastic wedge mounted on collimator. This finding suggests that plastic wedges can help improve image quality of whole foot radiography with one radiation exposure.
Licence and reuse
Open access. This article is licensed under a Creative Commons Attribution 3.0 Licence (CC BY 3.0), as printed on the article, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original authors and the source. No permission is needed.
How to reuse this articleResponses (0)
About this article
Lorlorm, P., Choiprasert, W., Tungjai, M. & Kothan, S. (2017). Effects of Plastic Wedges on Whole Foot Radiograph in Anteroposterior and Oblique Positions. American Journal of Applied Sciences, 14(4), 511–516. https://doi.org/10.3844/ajassp.2017.511.516
- Licence
- CC BY 3.0
- Issue
- Volume 14, Issue 4
- Policies
- Editorial independenceUse of generative AIData availabilityAppeals and complaints
- Version
- Version of record
