Development of Porous Ti-6Al-4V Mix with Palm Stearin Binder by Metal Injection Molding Technique
Mohamad Ikhwan Jamaludin1, Nur Atikah Abu Kasim1, Nor Hafiez Mohamad Nor1 & Muhammad Hussain Ismail1 Show affiliations
- Centre for Advanced Materials Research (CAMAR), Faculty of Mechanical Engineering, University Technology of MARA (UiTM), 40450 Shah Alam, Selangor, Malaysia
American Journal of Applied Sciences, Volume 12, Issue 10, pp. 742–751 · doi.org/10.3844/ajassp.2015.742.751
Abstract
Good potential of biocompatibility and excellent mechanical properties, porous Ti-6Al-4V has become a great interest for biomedical applications. In this study, porous Ti-6Al-4V was fabricated by Metal Injection Molding (MIM) using Palm Stearin (PS) and Polyethylene (PE) binder together with sodium chloride (NaCl) as a space holder. Rheological characterization was performed to evaluate the flowability of the feedstocks for injection molding and the feedstocks exhibited a pseudoplastic behavior which is suitable for injection. The as-sintered parts were fabricated as the mixing, injection molding, debinding and sintering were conducted successfully. The mechanical properties of the as-sintered parts were investigated via tensile test and the results obtained were closed with the established range. Shrinkage, density and X-Ray Diffractometry (XRD) of the as-sintered parts were compared with the theoretical values which were found closed to the acceptable ranges. The microstructure of the surface and cross-section were observed under Scanning Electron Micrograph (SEM) and optical microscope to analyze the specimens before and after sintering. Generally, palm stearin binder system added with space holder to fabricate porous Ti-6Al-4V by MIM is feasible and has shown a good potential for biomedical applications.
Licence and reuse
Open access. This article is licensed under a Creative Commons Attribution 3.0 Licence (CC BY 3.0), as printed on the article, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original authors and the source. No permission is needed.
How to reuse this articleResponses (0)
About this article
Jamaludin, M. I., Kasim, N. A. A., Nor, N. H. M. & Ismail, M. H. (2015). Development of Porous Ti-6Al-4V Mix with Palm Stearin Binder by Metal Injection Molding Technique. American Journal of Applied Sciences, 12(10), 742–751. https://doi.org/10.3844/ajassp.2015.742.751
- Licence
- CC BY 3.0
- Issue
- Volume 12, Issue 10
- Policies
- Editorial independenceUse of generative AIData availabilityAppeals and complaints
- Version
- Version of record