Influence of Fasteners Disposition on Behaviour of Timber-Framed Walls with Double Fibre-Plaster Coating Boards
M.Kuhta & M.Premrov
American Journal of Applied Sciences, Volume 5, Issue 1, pp. 1–6 · doi.org/10.3844/ajassp.2008.1.6
Abstract
This paper provides experimental analysis of timber-framed walls, coated with double fibre-plaster coating boards fastened to the timber frame. As the walls under a horizontal load actually behave like a deep composite beam, the fasteners disposition is very important and directly influences bearing capacity and stiffness of the wall. Therefore, three different groups of test samples with staple distances of s = 37.5, 75 and 150 mm were experimentally analysed and compared. For groups G2 and G3 the failure of FPB occurred. It has been shown that proposed simplified Eurocode 5 methods, applicable for wood-based sheathing board might be unsuitable for the problems presented.
Licence and reuse
Free to read. This article carries the publisher’s copyright, as printed on it: © 2008 Science Publications. It is free to read; ask us before reusing it.
How to reuse this articleResponses (0)
About this article
M.Kuhta, & M.Premrov, (2008). Influence of Fasteners Disposition on Behaviour of Timber-Framed Walls with Double Fibre-Plaster Coating Boards. American Journal of Applied Sciences, 5(1), 1–6. https://doi.org/10.3844/ajassp.2008.1.6
- Licence
- © Science Publications
- Issue
- Volume 5, Issue 1
- Policies
- Editorial independenceUse of generative AIData availabilityAppeals and complaints
- Version
- Version of record